Place of Origin: | China (Mainland) |
---|---|
Brand Name: | ShangFang |
Model Number: | TC-03 |
Temperature: | Temperature Displayer |
Quick Details
Specifications
Features
Temperature Control/Light Control
Manual defrost by turning off
automatic defrost by turning off
Time/temp.setting to end defrost
Value Storing/Selt Testing
Technical Data
Range of temperature display:—45~99℃
Range of set temperature:—45~45℃
Accuracy:±1℃
Compressor: N.O. 30A/250VAC
Light: N.O. 30A/250VAC
Dimension:118(Length)×44(Width)×35(Depth)mm
Mounting hole dimension:87(Length)×34.5(Width)mm
Parameters
Temperature Control/Light Control
Manual defrost by turning off
automatic defrost by turning off
Time/temp.setting to end defrost
Value Storing/Selt Testing
Technical Data
Range of temperature display:—45~99℃
Range of set temperature:—45~45℃
Accuracy:±1℃
Compressor: N.O. 30A/250VAC
Light: N.O. 30A/250VAC
Dimension:118(Length)×44(Width)×35(Depth)mm
Mounting hole dimension:87(Length)×34.5(Width)mm
Parameters
Parameter
|
Function
|
Set range
|
Default
|
E1
|
Lower setpoint limit
|
-45℃~Set temp.
|
-35℃
|
E2
|
Higher setpoint limit
|
Set temp.~45℃
|
20℃
|
E3
|
Temp.Hysteresis
|
1~10℃
|
4℃
|
E4
|
Comp.start delay time
|
0~10Min
|
2Min
|
E5
|
Offset on room temp.
|
-10~10℃
|
0
|
E6
|
Offset on evap.Temp.
|
-10~10℃
|
0
|
F1
|
Max.Defrost duration
|
1~60Min
|
20Min
|
F2
|
Defrost interval time
|
0~24Hr
|
6Hr
|
F3
|
Defrost termination temp.
|
0~20℃
|
8℃
|