| Place of Origin: | China (Mainland) |
|---|---|
| Brand Name: | ShangFang |
| Model Number: | PN02 |
| Temperature: | Thermostat (fresh) |
Quick Details
Specifications
Features
Temperature Control
Manual/automatic defrost by turning off
Time/temp.setting to end defrost
High,Low temperature alarm
Re-start delay
Self Testing
Parameter Locking
Technical Data
Range of temperature displayed : -45~100℃(-45~120℉)
Range of set temperature: -45~45℃ (-45~120℉)
Accuracy:±1℃
Comperssor relay: 30A/250VAC
Dimension:142(Length)×38(Width)×35(Depth)mm
Mounting hole dimension:137(Length)×31.5(Width)
Parameters
Temperature Control
Manual/automatic defrost by turning off
Time/temp.setting to end defrost
High,Low temperature alarm
Re-start delay
Self Testing
Parameter Locking
Technical Data
Range of temperature displayed : -45~100℃(-45~120℉)
Range of set temperature: -45~45℃ (-45~120℉)
Accuracy:±1℃
Comperssor relay: 30A/250VAC
Dimension:142(Length)×38(Width)×35(Depth)mm
Mounting hole dimension:137(Length)×31.5(Width)
Parameters
|
Paramete
|
Function
|
Set range
|
Default
|
|
E1
|
Lower setpoint limit
|
-45℃/-40℉~Set temp.
|
-30℃/-31℉
|
|
E2
|
Higher setpoint limit
|
Set temp.~45℃/120℉
|
45℃/120℉
|
|
E3
|
Temp.hysteresis
|
1~20℃/1~36℉
|
4℃/7℉
|
|
E4
|
Comp.start delay time
|
0~10Min
|
2Min
|
|
E5
|
Offset on room temp.
|
-20~20℃/℉
|
0
|
|
E6
|
Offset on evap.temp.
|
-20~20℃/℉
|
0
|
|
C1
|
Temperature unit
|
0=℃ 1=℉
|
0
|
|
F1
|
Max.Defrost duration
|
1~60Min
|
20Min
|
|
F2
|
Defrost interval time
|
0~24Hr
|
6Hr
|
|
F3
|
Defrost termination temp.
|
0~30℃/32~86℉
|
8℃/46℉
|
|
F4
|
Display during defrost
|
0=Normal display
1=Last value before defrost |
0
|
|
F5
|
Fan operating function
|
0=Parallel with comp.
1=Continuous running except defrost
|
0
|
|
F6
|
Dripping time
|
1~10Min
|
2Min
|
|
F7
|
Fan start delay mode after defrosting
|
0=Temperature 1=Time
|
1
|
|
F8
|
Fan start delay time after defrosting
|
1~10Min
|
2Min
|
|
F9
|
Fan start delay temp. after defrosting
|
-30~30℃/-22~86℉
|
5℃/41℉
|