Place of Origin: | China (Mainland) |
---|---|
Brand Name: | |
Model Number: |
Quick Details
Specifications
RE023A PON Optical Power Meter is an upgraded version of RE023 PON power meter, it aims at the FTTx application and maintenance which not only can be used to test and estimate the signals of the voice, data and video at the same time, but also can be used to test the continues wave light power. The calibrated wavelengths for CW light power measurements includes 850, 1300,1310,1490,1550,1625nm. It is an essential and ideal tester for the construction and maintenance of the PON projects.
Brief introduction:PON optical power meter, 1260~1360/1470~1505/1535~1570nm, 1310/1490nm 2 calibrated wavelength, dynamic range–40 ~+10dBm(1550nm dynamic range-40 ~+20dBm), hand held, OPM included,FC/PC adaptor.
Features
Providing simultaneous measurement at all three wavelengths on the fiber (1490nm, 1550nm,1310nm )
Used in Burst mode measurement of 1310nm upstream
CW light power measurement is available with wavelengths of 850,1300,1310,1490,1550,1625nm.
USB communication port enables data transfer to a PC
1000 measurement items can be saved in JW3212A PON power meter or computer for data review.
RE023A PON power meter offers up to 10 different threshold sets in total; Three status LEDs represent different optical signal conditions of Pass,
Warn and Fail respectively.
User self-calibration can be performed and “Factory Default” mode can be retrieved in computer through the software.
PON SC standard connector, easy to test, other type connector port can be required on customer requests.
Backlight LCD display supports night operation.
10 minutes Auto-off function can be activated or deactivated with keypad operation.
Specification
Item
|
Specifications
|
1310nm upstream measurement
|
|
Pass zone (nm)
|
1260~1360
|
Isolation @1490/1550nm(dB)
|
>40
|
Measurement Range (dBm)
|
-40~+10
|
1490nm downstream measurement
|
|
Pass zone (nm)
|
1470~1505
|
Isolation @1550nm(dB)
|
>30
|
Isolation @1310nm(dB)
|
>40
|
Measurement Range (dBm)
|
-40~+10
|
1550nm downstream measurement
|
|
Pass zone (nm)
|
1535~1570
|
Isolation @1490nm(dB)
|
>40
|
Isolation @1310nm(dB)
|
>40
|
Measurement Range (dBm)
|
-40~+25
|
Measurement Accuracy
|
|
Connatural Uncertainty (dB)
|
±0.5
|
Linearity (dB)
|
±0.1
|
Passing through insertion Loss (dB)
|
<1.5
|
CW light power measurements
|
|
Wavelength(nm)
|
800~1700nm
|
Measurement Range (dBm)
|
-70~+6
|
Uncertainty
|
±5%
|
Calibrated Wavelength(nm)
|
850,1300,1310,1490,1550,1625
|
Resolution(dB)
|
0.01
|
Optical Connector
|
FC(interchangeable SC,ST)
|
General Specifications
|
|
Display
|
Graphic display, Resolution is : 128*64
|
Measurement Unit
|
dBm,dB and xW
|
Resolution
|
0.01dB
|
Power Supply
|
1.5V AA Alkaline Batteries (3pcs)
|
Battery Life
|
80 hours
|
Operating Temperature
|
-10℃ ~ +60℃
|
Storage Temperature
|
-25℃ ~ +70℃
|
Net Weight
|
550g
|
Dimensions
|
210X115X55
|