Product Main

Quick Details

Place of Origin:
Brand Name: ShangFang
Model Number: ED106
Usage: Temperature Sensor
Theory: refrigeration
Output: Digital Sensor
Dimension: 77(Length)×35(Width)×60(Depth)mm

Specifications

Features 
Temperature control
Evaporator fan control
Automatic/manual defrost
Defrost by electric heater
Time/temp. seting to end defrost
Re-start delay
Celsius/Fahrenheit degrees 

Technical Data 
Range of temperature display:-45~100℃  (-40~120℉)
Range of set temperature:-45~45℃  (-40~120℉)
Accuracy:±1℃ (±2℉)
Compressor: N.O. 20A/250VAC
Defrost: N.O. 10A/250VAC
Evap. Fan: N.O. 5A/250VAC
Dimension:77(Length)×35(Width)×60(Depth)mm
Mounting hole dimension:71(Length)×29(Width)mm
 
Parameters  

 
Paramete
Function
Set range
Default
E1
Lower setpoint limit
-45℃/-45℉~Set temp.
-35℃/-31℉
E2
Higher setpoint limit
Set temp.~45℃/120℉
45℃/120℉
E3
Temp.hysteresis
1~20℃/1~36℉
4℃/7℉
E4
Comp.start delay time
0~10Min
2Min
E5
Offset on room temp.
-20~20℃/℉
0
E6
Offset on evap.temp.
-20~20℃/℉
0
C1
Temperature unit
0=℃   1=℉
0
F1
Max.Defrost duration
1~60Min
20Min
F2
Defrost interval time
0~24Hr
6Hr
F3
Defrost termination temp.
0~30℃/32~86℉
8℃/46℉
F4
Display during defrost
0=Normal display
1=Last value before defrost
0
F5
Fan operating function
0=Parallel with comp.
1=Continuous running except defrost
0
F6
Dripping time
0~10Min
2Min
F7
Fan operating function after defrost end
0=Temperature 1=Time
1
F8
Fan start-up delay after defrosting
0~10Min
2Min
F9
Fan start temperature after defrost end
-30~30℃/-22~86℉
5℃/41℉