| Classification: | Laboratory Thermostatic Devices |
|---|---|
| Brand Name: | RUCHENG |
| Classification: | / |
| Certification: | / |
| Capacity: | / |
| Condition: | / |
| Place of Origin: | China (Mainland) |
| Model Number: | DH2000-1, DH2000-2, DH2000-4 |
Quick Details
Specifications
Dry bath incubator is a sample incubation equipment based on film heating and PID automatic temperature control technology. Flexible timing, constant temperature function and unique multi-point operating mode improve the efficiency of the laboratory work, which is the ideal equipment for samples incubation, catalytic reaction process, saving and etc.
Features:
U Colorful LCD display(320x480 Pixel), easy to set up and use.
U Accurate temperature control, high stability.
U Different blocks for choice. Customized blocks are accepted.
U Temperature calibration function.
U Three kinds of countdown trigger modes available.
U External temperature sensor can be connected.
U MAgnetic dust-prooflid can be optionally supplied(for DH2000-1 or DH2000-2).
U Built-in software and hardware over temperature protection device, will use more reliable.
Parameters:
Model |
DH2000-1 |
DH2000-2 |
DH2000-4 |
Temp. setting range |
0℃~160℃ |
0℃~160℃ |
0℃~130℃ |
Temp. range |
RT+5℃~160℃ |
RT+5℃~160℃ |
RT+5℃~130℃ |
Time range |
1min~99h59min/∞ |
1min~99h59min/∞ |
1min~99h59min/∞ |
Temp. accuracy |
≤±0.1℃@37℃ ≤±1℃@120℃ |
≤±0.1℃@37℃ ≤±1℃@120℃ |
≤±0.2℃@37℃ ≤±1℃@120℃ |
Display accuracy |
0.1℃ |
0.1℃ |
0.1℃ |
Temp. uniformity |
≤±0.1℃@37℃ |
≤±0.1℃@37℃ |
≤±0.2℃@37℃ |
Heating rate |
1°C/min, 3°C/min, 5°C/min,AUTO |
1°C/min, 3°C/min, 5°C/min,AUTO |
1°C/min, 3°C/min, 5°C/min,AUTO |
Heating time(AUTO) |
≤25min(fROM 25℃ to 160℃) |
≤25min(fROM 25℃ to 160℃) |
≤20min(fROM 25℃ to 130℃) |
Program number |
99programs |
99programs |
99programs |
MulTi points running |
Yes(Max 5 points) |
Yes(Max 5 points) |
Yes(Max 5 points) |
Multicycle |
Yes(Max 99 times) |
Yes(Max 99 times) |
Yes(Max 99 times) |
AutopreHeating |
Yes |
Yes |
Yes |
Auto running |
Yes |
Yes |
Yes |
Auto resume to run |
Yes |
Yes |
Yes |
Auto constant temp. at the end of run |
Yes |
Yes |
Yes |
External temperature sensor Interface |
1port interface |
1port interface |
1port interface |
Block quantity |
1 |
2 |
4 |
Power |
200W |
400W |
500W |
Voltage |
AC220V or AC110V/50-60Hz |
AC220V or AC110V/50-60Hz |
AC220V or AC110V/50-60Hz |
Fuse |
250V 3A 520 |
250V 3A 520 |
250V 3A 520 |
Dimension(mm) |
320x205x110 |
320x205x110 |
385x205x110 |
Weight(kg) |
4.8 |
6.1 |
8.8 |
Optional Blocks:
Model |
TubeDiameter |
Capacity |
Model |
TubeDiameter |
Capacity |
MD01 |
6mm |
48 |
MD10 |
26mm |
8 |
MD02 |
7mm |
48 |
MD11 |
28mm |
4 |
MD03 |
10mm |
24 |
MD12 |
40mm |
3 |
MD04 |
12mm |
24 |
MD13 |
0.2ml centrifuge tube |
48 |
MD05 |
13mm |
24 |
MD14 |
0.5ml centrifuge tube |
48 |
MD06 |
15mm |
16 |
MD15 |
1.5ml centrifuge tube |
24 |
MD07 |
16mm |
16 |
MD16 |
2.0ml centrifuge tube |
24 |
MD08 |
19mm |
12 |
MD17* |
0.2mlPCR plate |
96 |
MD09 |
20mm |
12 |
MD18* |
0.2mlElisa plate |
Flat bottom |
*MD17 and MD18 is special for DH2000-2/DH2000-4