Air Source Swimming Pool Heat Pump for Heating & Cooling with Titanium Exchanger
.
1. Elegant cabinet.
2. Reliable compressor.
3. Titanium Heat exchange
4. Auto-defrosting.
2. Reliable compressor.
3. Titanium Heat exchange
4. Auto-defrosting.
Swimming Pool Heat Pump general features:
1. Automatic operation mode
2. Auto-restart, Auto defrosts.
3. Friendly and intelligent LCD Control panel interface.
4. Both cooling & heating mode are optional
5. Wide working range: ambient temp: -7 oC to 43oC
6. Adopt world famous Copeland compressor.
7. Green refrigerant R410a/R407c
2. Auto-restart, Auto defrosts.
3. Friendly and intelligent LCD Control panel interface.
4. Both cooling & heating mode are optional
5. Wide working range: ambient temp: -7 oC to 43oC
6. Adopt world famous Copeland compressor.
7. Green refrigerant R410a/R407c
New Times pool heat pump advantage
1. Heating capacity ranged from 7kW, 220V/1ph/50Hz to 230kW, 380V/3ph/50Hz
2. Long operating life: Using the advanced stainless steel/titanium heat exchanger, which resists the erosion from chlorine in the water, creates a longer life span.
2. Long operating life: Using the advanced stainless steel/titanium heat exchanger, which resists the erosion from chlorine in the water, creates a longer life span.
3. Design for comprehensive anti-corrosion feature:
1) Special case design adopting stainless steel bolts and nuts. The holes for bolts are designed to avoid damaging the coating.
2) Durable coating in white or stainless steel is available
4. Special design for the fan shroud, with accurate and equal distance between the fans
1) Special case design adopting stainless steel bolts and nuts. The holes for bolts are designed to avoid damaging the coating.
2) Durable coating in white or stainless steel is available
4. Special design for the fan shroud, with accurate and equal distance between the fans
blades and fan shroud, low vibration, and low noise when running.
5. Intelligent defrosting with revert circuit.
6. With cover on remote wire control panel, water proof
7. Available refrigerant: R22/ R407C/ R410A.
8. The unit is remarkably compact, with flow switch built inside.
9. Safety: Water and electricity are separately insulated, without electric shock.
5. Intelligent defrosting with revert circuit.
6. With cover on remote wire control panel, water proof
7. Available refrigerant: R22/ R407C/ R410A.
8. The unit is remarkably compact, with flow switch built inside.
9. Safety: Water and electricity are separately insulated, without electric shock.
10. Warranty: one year guarantee for the whole units.
Swimming Pool Heat Pump water heater Parameters
| Model | HLRD9-YC | HLRD15-YC | HLRD24-YC | HLRD30-YC | HLRD36-YC | HLRD45-YC | HLRD60-YC | HLRD75-YC | HLRD95-YC | HLRD125-YC | HLRD150-YC | |||||||
| Heating Capacity | kW | 13.5 | 21.3 | 35.5 | 45.5 | 52.8 | 66 | 87.4 | 110 | 140 | 191 | 230 | ||||||
| COP | ---- | 4.33 | 4.96 | 4.87 | 4.84 | 4.74 | 4.46 | 4.65 | 4.73 | 4.87 | 5.08 | 4.94 | ||||||
| Cooling Capacity | kW | 8.8 | 14.7 | 25.5 | 30.5 | 35.8 | 44.9 | 59.5 | 75 | 95.2 | 126.9 | 150 | ||||||
| EER | ---- | 2.67 | 2.68 | 3 | 2.78 | 3.12 | 2.78 | 2.71 | 2.8 | 3.2 | 2.89 | 2.79 | ||||||
| Max Water Outlet Temperature | °C | 45 | ||||||||||||||||
| Rated Input Power (Heating/Cooling) | kW | 3.12/3.30 | 4.3/5.50 | 7.30/8.50 | 9.4/11.00 | 11.15/11.50 | 14.80/16.20 | 18.80/22.00 | 23.30/26.80 | 28.80/29.80 | 37.60/44.00 | 46.60/53.80 | ||||||
| Rated Input Current (Heating/ Cooling) | A | 14.5/15.3 | 6.5/9.9 | 11/13.4 | 14.2/19.8 | 20.1/19.24 | 28.2/30.1 | 33.9/39.7 | 42.0/48.3 | 51.92/53.7 | 67.8/79.4 | 84.00/96.6 | ||||||
| Max Input Power | kW | 3.4 | 6.1 | 10 | 13.5 | 15.1 | 18.9 | 25.4 | 31.5 | 38.75 | 50.8 | 63 | ||||||
| Max Input Current | A | 15.5 | 9.2 | 15.2 | 20.6 | 27.2 | 34.1 | 45.8 | 56.8 | 69.86 | 91.6 | 113.6 | ||||||
| Power Supply | V/Hz/Ph | 220-240V/50Hz1Ph | 380V-400V /50Hz/3Ph | |||||||||||||||
| Compressor Type | Scroll | |||||||||||||||||
| Number of Compressors | 1 | 1 | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 4 | 4 | 4 | ||||||
| Heat Exchanger | Tube in tube titanium heat exchanger/Titanium tube in PVC shell | |||||||||||||||||
| Throttling device | Emerson thermal expansion valve | |||||||||||||||||
| Fan type | Low noise high efficiency axial type | |||||||||||||||||
| Fan Direction | Vertical | |||||||||||||||||
| Number of Fans | 1 | 1 | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 4 | 4 | |||||||
| Fan Air Flow Volume | m3/h | 3900 | 6500 | 13000 | 13000 | 15600 | 19500 | 26000 | 32500 | 39000 | 65600 | 78000 | ||||||
| Fan Power Input | W | 180 | 260 | 320×2 | 320×2 | 550×2 | 550×2 | 640x2 | 1100x2 | 1100x2 | 640x4 | 1100x4 | ||||||
| Fan Rotation Speed | RPM | 850 | 850 | 790 | 790 | 820 | 820 | 790 | 820 | 820 | 790 | 820 | ||||||
| Ambient Temperature | °C | -10°C~43°C | ||||||||||||||||
| Refrigerant/Chare Qty | kg | R407C/1.5 | R407C/1.9 | R407C/1.7*2 | R407C/3.8 | R407C/2.2*2 | R407C/3.5*2 | R407C/4.5*2 | R407C/5.5*2 | R407C/6.5*2 | ||||||||
| Noise | dB (A) | ≤54 | ≤56 | ≤61 | ≤61 | ≤66 | ≤66 | ≤66 | ≤68 | 68 | 71 | 72 | ||||||
| Piping Diameter | mm | DN40 | DN40 | DN50 | DN50 | DN50 | DN65 | DN65 | DN80 | DN80 | DN80 | DN100 | ||||||
| Cabinet | galvanized powder coated steel | |||||||||||||||||
| Discharge Pressure | Mpa | 2.5 | 2.5 | 2.5 | 2.5 | 2.5 | 2.5 | 2.5 | 2.5 | 2.5 | 2.5 | 2.5 | ||||||
| Suction Pressure | Mpa | 0.3-0.8 | 0.3-0.8 | 0.3-0.8 | 0.3-0.8 | 0.3-0.8 | 0.3-0.8 | 0.3-0.8 | 0.3-0.8 | 0.3-0.8 | 0.3-0.8 | 0.3-0.8 | ||||||
| Rated Water Pressure | Mpa | 0.2~0.6 | ||||||||||||||||
| Max Water-in Pressure | Mpa | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | |||||||
| Min Water-in Pressure | Mpa | / | / | / | / | / | / | / | / | / | / | |||||||
| Water Flow Volume | m3/h | 2.52 | 3.77 | 7.54 | 9.05 | 11.31 | 14.98 | 18.86 | 24 | 32.74 | 39.43 | |||||||
| Product Dimensions | mm | 695/688/740 | 706/746/940 | 1450/750/1065 | 1450/750/1065 | 1450/750/1265 | 1445/850/1850 | 1990/980/2050 | 1990/980/2050 | 1900/1020/2050 | 2015/2200/2025 | 2015/2200/2025 | ||||||
| Shipping Weight | kg | 131 | 157 | 292 | 316 | 487 | 622 | 656 | 785 | 1052 | 1468 | |||||||
| Testing condition | 1. Heating working condition: Outdoor DB/WB temp = 24°C/19°C,62.5%RH, inlet/outlet water temp = 26°C/28°C.2. Cooling working condition: Outdoor DB/WB temp = 35°C/24°C,68%RH, inlet/outlet water temp = 30°C/28°C. | |||||||||||||||||
Exhibitions
Recently we attended the following Exhibition:
MCE Exhibition Milan of Italy (Mar.23-27th,2010)
CRH Exhibiton Beijing of China (Apr.7-9th,2010)
FRIGAIR Exhibition Johannesburg of South Africa (Sep.8-11th,2010)
CLIMATIZACION 2011 of Madrid --Spain(2011.3.1-4).
FEBRAVA 2011 of--Sao Paulo--Brasil;(2011.9.20-23)
FIHAV-HAVANA INTERNATIONAL FAIR 2011(2011.10.31-11.05)
BIG 5 (INTERNATIONAL BUILDING&CONSTRUCTION SHOW)of Dubai (2011.110.21-24)
MCE Exhibition Milan of Italy (Mar.27-30th,2012)
CRH Exhibiton Beijing of China (Apr.11-13th,2012)
Chillventa 2012 of Nürnberg, Germany (Oct. 09-11th, 2012)
Bombay Convention and Exhibition,India(Dec.20-22th,2012)