Place of Origin: | China (Mainland) |
---|---|
Brand Name: | TOP Oil Purifier |
Model Number: | ZYD-30 Oil Purifier |
Quick Details
Specifications
Mobile trailer type transformer oil reclaiming system degassing, drying and particulate removal, removal of acidity, sludge
The Mobile Regeneration System (Model ZYD-M) has been specially designed for on site use to
completely regenerate insulating oils in energized or de-energized transformers. The ZYD system
provides regular oil purification such as degassing, drying and particulate removal but its main application
is inthe removal of acidity, sludge, other soluble oil decay products and discoloration. This is accomplished
by theuse of high vacuum degasification technology and particulate filters combined with our special brand
of earth. The ZYD Model is mounted on a leak proof base and can be installed and operated on a trailer.
Features:
1. Besides the common vacuum oil purifier's function of dewatering, degassing and eliminating impurities,
this machine can regenerate the seriously deteriorated oil by removing the polarity materials, such as the deep
oxides, free carbon in the oil effectively. It can make the seriously deteriorated oil reach to the normal index
like anti-oxides, acid-alkali water-solubility.
2. Programmable Logic Controller (P. L. C)
3. Three ways of using: the vacuum dewatering, degassing, removing impurities system can work independently,
so dose the regeneration oil system, and also they can work at the same time.
4. The performance and lifetime of insulating oil will improve and extend awfully after purification and regeneration.
Advantages:
It can not only removing the water, gas and impurities which mixed in the oil, but also can improve many values
reach to the national standard such as the acid value, PH value. Meanwhile, it improves the voltage-withstand value through filtering the polarity materials like free carbon, deep oxides and so on.
Technical Parameters:
Index name |
unit |
ZYD-30 |
ZYD-50 |
ZYD-100 |
ZYD-150 |
ZYD-200 |
ZYD-250 |
ZYD-300 |
|
Flow rate |
L/H |
1800 |
3000 |
6000 |
9000 |
12000 |
15000 |
18000 |
|
Working vaccum |
MPa |
-0.08~-0.099 |
|||||||
Working pressure |
MPa |
≤ 0.4 |
|||||||
Temperature range |
°C |
20 ~80 |
|||||||
Dielectric strength |
KV |
≥ 70 |
|||||||
Water content |
ppm |
≤ 3 |
|||||||
Gas content |
% |
≤ 0.1 |
|||||||
Particles size |
μ |
≤ 1 |
|||||||
Power supply |
|
380V 50HZ 3Ph (As per user's option) |
|||||||
Working noise |
dB(A) |
≤65~85 |
|||||||
Heating power |
Kw |
30 |
30 |
95 |
110 |
125 |
136 |
151 |
|
Total power |
Kw |
35.5 |
37.5 |
104 |
121 |
135 |
148 |
168 |
|
Inlet(Outlet) |
mm |
Φ25 |
Φ25 |
Φ42 |
Φ50 |
Φ50 |
Φ60 |
Φ60 |
|
Weight |
kg |
450 |
550 |
870 |
950 |
1250 |
1850 |
2100 |
|
Dimension |
L |
mm |
1500 |
1500 |
1950 |
2100 |
2200 |
2250 |
2400 |
W |
mm |
1250 |
1250 |
1300 |
1350 |
1350 |
1400 |
1450 |
|
H |
mm |
1700 |
1750 |
2100 |
2200 |
2200 |
2200 |
2200 |