| Place of Origin: | China (Mainland) |
|---|---|
| Brand Name: | Zemic |
| Model Number: | L6D |
| Usage: | |
| Theory: | |
| Output: |
Quick Details
Specifications
Zemic L6D load cells are available in the capacities 2.5kg to 50kg.
Alumium construction with parallel beam.
Silicon adhesive sealed, surface anodized and anti-corrosion.
Intergral structure and easy installation.
Suitable for pricing scale, platform scale and other electronic
Weighing devices. Features
Capacity: 2.5kg to 50kg.
High accuracy...
Max. Platform size: 250x350mm.
Intergral installation.
With OIML approval.
| Capacity | 2.5/3/5/6/8/10/15/20/30/35/40/50 | |||
| Accuracy | kg | C3D | C3 | C3G |
| Approvals | OIML R60 C3 | |||
|
Maximum numberof verification intervals |
n max | 2500 | 3000 | 4000 |
|
Minimum load cell verification interval |
v min | Emax/5000 | Emax/7000 | Emax/11000 |
| Combined error | (%FS) | ≤ ± 0.030 | ≤ ± 0.020 | ≤ ± 0.015 |
| Creep | (%FS/30min) | ≤ ± 0.020 | ≤ ± 0.0167 | ≤ ± 0.0125 |
|
Temperature effect on sensitivity |
(%FS/10) | ≤ ± 0.021 | ≤ ± 0.0175 | ≤ ± 0.0131 |
| Temperature effect on zero | (%FS/10) | ≤ ± 0.028 | ≤ ± 0.020 | ≤ ± 0.0127 |
| Output sensitivity | (mv/v) | 2.0± 0.2 | ||
| Input resistance | (Ω ) | 409± 6/1065± 15 | ||
| Output resistance | (Ω ) | 350± 3/1000± 10 | ||
| Insulation resistance | (MΩ ) | ≥ 5000(50VDC) | ||
| Zero balance | (%FS) | 2 | ||
| Temperature, compensated | () | -10~+40 | ||
| Temperature, operating | () | -35~+65 | ||
| Excitation, Recommended | (V) | 5~12(DC) | ||
| Excitation, Max | (V) | 18(DC) | ||
| Safe overload | (%FS) | 150 | ||
| Ultimate overload | (%FS) | 300 | ||
| Corner correction | 0.02% load value/100mm | |||