L6N load cells are available in the capacities 3kg to 100kg.
Alumium construction with parallel beam.
Silicon adhesive sealed, surface anodized and anti-corrosion.
Intergral structure and easy installation.
Suitable for electronic balance and other electronic
Weighing devices. Features
Capacity: 3kg to 100kg.
High accuracy.
Max. Platform size:
400X400mm.
With OIML approval.
Capacity |
(kg) |
3/5/8/10/15/20/30/40/50/75/100 |
Accuracy |
|
C3 |
Approvals |
|
OIML R60 C3 |
Maximum number of verification intervals |
n max |
3000 |
Minimum load cell verification interval |
v min |
Emax/7000 |
Combined error |
(%FS) |
≤ ± 0.020 |
Creep |
(%FS/30min) |
≤ ± 0.0167 |
Temperature effect on sensitivity |
(%FS/10) |
≤ ± 0.0175 |
Temperature effect on zero |
(%FS/10) |
≤ ± 0.020 |
Output sensitivity |
(mv/v) |
2.0± 0.2 |
Input resistance |
(Ω ) |
406± 6 |
Output resistance |
(Ω ) |
350± 3 |
Insulation resistance |
(MΩ ) |
≥ 5000(50VDC) |
Zero balance |
(%FS) |
2 |
Temperature, compensated |
() |
-10~+40 |
Temperature, operating |
() |
-35~+65 |
Excitation, Recommended |
(V) |
5~12(DC) |
Excitation, Max |
(V) |
18(DC) |
Safe overload |
(%FS) |
150 |
Ultimate overload |
(%FS) |
300 |
Corner correction |
|
0.02% load value/100mm |