Part of Anesthesia
Main body High-strength engineering plastic rack, light,
Beautiful and corrosion resistant
Scope of application adult, child
Gas source O2, N2O: 0.27~0.55MPa
Flow meter O2: 0.1~1.0L/min 1.1~10L/min
Flow rate of rapid oxygen supply 25~75L/min
Vaporizer Among Halothane, Enflurane, Isoflurane and Sevoflurane, one can be chosen for application as required by the customer.
Respiratory circuit working mode: All-close, semi-close, semi-open
Releasing pressure: 1~4 kPa
Respiratory bellows bellows for adults, bellows for children
Tidal volume range: 0~1500 ml
Part of Ventilator
Display mode High-definition 4.8" LCD screen display
Ventilation mode IPPV, MANUAL (Manual monitoring of tidal volume, ventilation volume, respiratory rate)
Ventilation parameters Tidal volume 50~1500ml
Rate 4~80 bpm
I: E 2: 1~1: 4
Pressure range 1.0~6.0 kPa
Parameters for ventilation monitoring tidal volume, ventilation volume, IPPV rate, I/E, peak pressure of airway, inspiratory trigger pressure, pressure - time waveform
Security Alarm System
Airway pressure alarm upper limit setting range 1.0~6.0 kPa
Low limit setting range 0.4~2.0 kPa
TV alarm upper limit setting range 0.5~2.0L
Low limit setting range 0.02~1.0L
Sustained high-pressure alarm it will give alarm when stress have consistently
Been higher than 2.5 kPa
Suffocation alarm it will give sound and light alarm if there is
No tidal volume input in 15s
Power alarm
Power AC 220V± 10% 50Hz± 1Hz
Main body High-strength engineering plastic rack, light,
Beautiful and corrosion resistant
Scope of application adult, child
Gas source O2, N2O: 0.27~0.55MPa
Flow meter O2: 0.1~1.0L/min 1.1~10L/min
Flow rate of rapid oxygen supply 25~75L/min
Vaporizer Among Halothane, Enflurane, Isoflurane and Sevoflurane, one can be chosen for application as required by the customer.
Respiratory circuit working mode: All-close, semi-close, semi-open
Releasing pressure: 1~4 kPa
Respiratory bellows bellows for adults, bellows for children
Tidal volume range: 0~1500 ml
Part of Ventilator
Display mode High-definition 4.8" LCD screen display
Ventilation mode IPPV, MANUAL (Manual monitoring of tidal volume, ventilation volume, respiratory rate)
Ventilation parameters Tidal volume 50~1500ml
Rate 4~80 bpm
I: E 2: 1~1: 4
Pressure range 1.0~6.0 kPa
Parameters for ventilation monitoring tidal volume, ventilation volume, IPPV rate, I/E, peak pressure of airway, inspiratory trigger pressure, pressure - time waveform
Security Alarm System
Airway pressure alarm upper limit setting range 1.0~6.0 kPa
Low limit setting range 0.4~2.0 kPa
TV alarm upper limit setting range 0.5~2.0L
Low limit setting range 0.02~1.0L
Sustained high-pressure alarm it will give alarm when stress have consistently
Been higher than 2.5 kPa
Suffocation alarm it will give sound and light alarm if there is
No tidal volume input in 15s
Power alarm
Power AC 220V± 10% 50Hz± 1Hz