Product Main

Quick Details

Place of Origin: China (Mainland)
Brand Name: ZKJD
Model Number: ZK40
Structure: Single-stage Pump
Usage: Water
Power: Electric
Standard or Nonstandard: Standard
Fuel:
Pressure: Low Pressure
Application: Submersible

Specifications

Pump/aquarium fish tank pumps are made in China

Specification
NO Items Specs
1 Sizes and weight 83x63x48;250g
2 Dimension of inlet 13.8mm
3 Dimension of outlet 10mm
4 Driving method  Brushless, Magnetic , 2 phase or 3 phase
5 Pump material PA66+GF30% (optional)
6 Condition of use Continuously
7 Fluids  Water, oil, gasoline, acid and alkali solution etc
8 Max working temp 60℃(2 phase)or 100℃(3 phase)
9 Power consumption 2.5W~26.4W
10 Rated voltage 12Vdc or 24Vdc
11 Voltage used 5Vdc ~ 12Vdc or 5Vdc ~ 24Vdc
12 Max rated current 1.2A
13 Max flow rate 10.8L/MIN(2.86G/MIN)
14 Max Static Head 7m(23ft)
15 Noise <35dB
16 Water proof class IP68(can be submersible installed)
17 Life span More than 30000hrs
18 Power supply Solar panel; DC electric source; battery

Features
Brushless, permanent magnetic rotor, maintenance-free, long life
small size, high efficiency, low consumption, low noise
Ceramic sleeve and ceramic shaft [optional]
Stator and circuit board sealed by epoxy resin, completely water proof
Parameter adjustable, 12v pump's head can be 2m to 5m..
Can be customized

Difference between 2-phase and 3-phase sensor less BLDC pump
2-Phase Drived by sensor which should be put inside the pump body
3-Phase Drived by program, sensor less, whole control circuit can be put outside
Speed adjustable by PWM, analog signals(0-5v) or potentiometer[optional]
Locked-rotor and reverse connection protection
Automatic overload protection and over-temperature protection
Soft start with low in-rush current, great for PV panel

Parameters (The technical specification only for reference, it can be customized)
model voltage Rated current head flow  power
 V A m ft L/H G/H   w
ZK40-0510 5 0.5 1.0 3.5 250 66 2.5
ZK40-0615 6 0.6 1.5 4.9 300 79 3.6
ZK40-0935 9 1.10 3.5 11.4 420 122 9.9
ZK40-1220 12 0.45 2.0 6.5 350 93 5.4
ZK40-1230 12 0.70 3.0 9.7 400 106 8.4
ZK40-1240 12 1.00 4.0 13.0 460 122 12.0
ZK40-1250 12 1.20 5.0 16.0 520 137 14.4
ZK40-2430 24 0.35 3.0 9.7 400 106 8.40
ZK40-2440 24 0.50 4.0 13.0 460 127 12.0
ZK40-2450 24 0.55 5.0 16.0 520 148 14.4
ZK40-2460 24 0.80 6.0 19.5 580 153 19.2
ZK40-2470 24 1.15 7.0 22.7 620 164 26.4
Remarks The current above is open outlet current, when contact to circulation system

the current will cut down to 55%~70% of Rated current.