Product Main

Quick Details

Place of Origin: China (Mainland)
Brand Name: Sun Gold Power
Model Number: 1000VA/600W
Phase: Single Phase
Protection: Full protection
Weight: 8.4
Output Voltage: 110V/120V/220V/230V/240V
Type: Standby
Application: Computer

Specifications


We have 500VA/300W , 800VA/480W , 1000VA/600W  , 1200VA/720W offline UPS .

Applied Scope :

Computer

Network Server
Workstation

Small Office Environment
Automatic Teller Machine
Monitoring System

 

Product details:

UPS standby in battery charging state in usual time. When the power supply unexpectedly shut down, the built-in inverter will urgently convert the battery output into AC to keep stable power supply. it is generally considered high rate, low noise while running and cost-effective, mostly used in comparably stable environment with a small fluctuation of utility power and lower requirement of power supply quality.

 

1.Intelligent CPU control and management, the function is rich

2.Adopt the full bridge inverter technology, the system more stable and reliable;

3.Wide input voltage and frequency range; Overload alarm message and automatic protection function;

4.The battery mode no-load automatic shutdown function

5.Depending on the type of perfect detection and overload, short circuit protection (battery mode);

6.At least the periphery of the circuit components, high reliability, easy maintenance;

7.Can match various generator is used

 

Technical specifications:


Model

500VA/300W

800VA/480W

1000VA/600W

1200VA/720W

Power factor

0.6

Load type

Personal computer and other PC peripheral devices

Mains voltage range

 (75-140) ±5Vac or (140~290) ±5Vac

Mains frequency range

(40~70)±1Hz

Output voltage range(Line mode)

110V/120V/220V/230V/240V±10%(Sine wave)

Output frequency range(Line mode)

Synch with mains input

Output voltage range(battery mode)

110V/120V/220V/230V/240V±10%(Square wave)

Output frequency range(battery mode)

(50/60)±1Hz(frequency self-adapt system)

Battery No-load protection

Auto protection. The UPS auto shutdown after 2min no load detected

Transfer time

≤8ms

Battery

Sealed lead acid maintenance-free battery

Battery number

12V/7AHx1pcs

12V/9AHx1pcs

12V/7AHx2pcs

12V/7AHx2pcs

Battery protection

Auto protection. The UPS auto shutdown when battery voltage is low or high.

Battery charging time

8 hours to 90%

Short circuit protection

Auto protection. Output shuts off and the buzzer beeps continuously

Overload protection

110%, buzzer beeps; load percentage >120%, output shuts off, buzzer beeps continuously.

Communication interface

USB

Network protection

RJ45/11 surge protector

Storage temperature

-15℃~45℃

Relative humidity

0%~90%(No condensation water)

Noise

≤35dB(1mfrom front panel)

Size/L×W×H(mm)

291*90*145

330*90*145

340x122x190

Net weight

4.5

5.2

8.4

9.4