Place of Origin: | China (Mainland) |
---|---|
Brand Name: | Refine Med |
Model Number: |
Quick Details
Specifications
Features
1. Can be used for all standards of sterile burette type infusion set for single use (Correspond ISO 8536-4:2007 standard).
2. Automatic Calibration for IV sets.
3. Five working modes: Rate mode, Time mode, Volumetric mode, Dose mode and Drug library mode
4. Built in rechargeable battery (Lithium-ion polymer battery).
5. Spec of the fuse: F1AL/250V, two (inside).
6. 8 hours internal battery backup.
7. Alarm functions: occlusion, empty bottle, low battery, rate error, end of infusion, door open, air in line etc
8. Three levels of the occlusion limited pressure: high, middle and low.
9. Three levels of alarm sound: high, middle and low.
10. The infusion pump goes into KVO mode automatically as infusion is completed.
11. Purge and Bolus functions
12. Anti-bolus function
13. History records being demanded directly. And with RS232 ports as well, in order to connect other equipments.
14. Waterproof class: IPX4
Technical Specification
1. Flow range : 1.0~99.9ml/h, 0.1ml/h increment
100~1200ml/h, 1ml/h increment
or 1~400drops/min, 1 drop/min increment.
2. Flow precision : ± 5%
3. Target volume (TAR VOL): 0.1~99.9ml, 0.1 ml increment; 100~9999 ml, 1ml increment.
4. Infusion time (TIME): 1min~6000min, increment 1min.
5. Adjustable range of infusion precision:-50%~+50%, increment:1% (for volumetric mode).
6. Infused Volume range: 0.1~99.9ml increment 0.1ml; 100~9999ml, 1ml increment.
7. Adjustable ranges of Sol. Vol, Drug Mass, Dose:
Sol. Vol (solution Volume): 1~9999 ml, increment: 1ml
8. Drug Mass: 0.1~999.9, increment: 0.1, Unit: g, mg, U, IU;
9. Dose: 0.001~9.999, increment: 0.001; 10.00~99.99, increment: 0.01;
10. 100.0~999.9, increment 0.1;1000~9999, increment 1;
11. Dose units: ng/kg/min; ug/kg/min; mg/kg/min; g/kg/min; Ug/kg/h; mg/kg/h; g/kg/h;
ug/min; mg/min; g/min; ug/h; mg/h; g/h; U/min; U/h; IU/h; U/kg/h; mg/kg; ml/min; ml/h;
12. Body Weight range: 0.1~300.0kg, increment: 0.1kg
13. Purge: 600 ml/h.
14. Bolus: Adjustable from 1~1200ml/h, in steps of 0.1ml/h (if flow rate < 100ml/h) and 1ml/h
(if flow rate > 100ml/h), Target Volume:1~500 ml, in steps of 1ml
15. KVO rate: if the flow rate ≤10 ml/h, KVO is 1ml/h.
Otherwise KVO is 3ml/h.
16. Power supply: AC100-240V, 50/60Hz, Internal Lithiumion polymer battery:DC 11.1V, ≥1600mAh.
The battery backup is approx. 8 hours (when using a fully charged battery and running at 20
drops/min with any standard IV Set).
17. Power consumption:≤25VA
18. Class: I
19. Type : CF
20. Size: 125mm(W)×230mm(H)×125mm(D)
21. Net weight: approx. 2kg
22. Operating condition:
Ambient temperature: 5~40 degree C,
Relative humidity: 20~90%
23. Storage condition:
Ambient temperature: -10~55 degree C
Relative humidity : 10~90%.