Product Main

Quick Details

Place of Origin: China (Mainland)
Brand Name: SUREWAY
Model Number: GC A90
Color: White
Size: 58CM*48CM*51CM
Weight: 50KG
Usage: Gas Chromatography
AEFC accuracy: 0.01psi

Specifications

Gas Chromatograph 
1.Introduction

GC A90 is made according to international standards, its technical feature and index are in the world high level.It is widely used for oil exploitation and refining, petrochemistry, fine chemicals,food safty,environmental protection, epidemic prevention, pharmacology, scientific research, etc.

2.Our advantages

  • We make holistic analysis scheme according to customer's requirement.
  • We choose the best configuration scheme to ensure the best performance.
  • We offer the expert-level pre-sale service and after-sale service. Futhermoreif you're our big customer, you can enjoy the VIP service that can appoint our engineer group.
  • We're the pioneer of the analytical method in all industries.

3.Main Instrumental Components 

 

1) Column Oven

  • Introduction:It is a key part and occupy a large proportion of of gas chromatograph. Its function is accommodate column  and control the column's working temperature precisely.
  • Parameter:

Column oven size:28cm*30*cm*18cm 

Operating temperature range: ambient temperature to 400°C;

Temperature precision:0.1°C

Hightest programmed heating rate120°C/min;

Column loss compensation (double channel)

Temperature variation in the oven is less than or equal to 1°C

High-speed heating and cooling.

Ensuring the repeatability of retention time.

 

2) Columns

There are two general types of column, packed column and capillary column. Its function is mainly used forsplitting different

components from compound and it directly influence the separation efficiency, stability and detection sensitivity.
Packed Columns

Packed columns contain a finely divided, inert, solid support  material (commonly based on diatomaceous earth) coated with liquid stationary phase.

Capillary Columns

 Capillary columns have an internal diameter of a few tenths of amillimeter, whose walls are coated with liquid stationary phase.

Its capacity is small but its separation efficiency is better than packed column.  

 

3).Detectors  

There are many detectors which can be used in gas chromatography. Different detectors will give different types of selectivity. 

According to various objects that be detected, different detectors will be installed on GC.

Flame ionization detector(FID)

Thermal conductivity detector(TCD)

Electron capture detector(ECD)

Nitrogen-phosphorus detector(NPD)

Flame photometric detector(FPD)

Photo-ionization detector(PID)

Pulsed discharge helium ionization detector(PDHID)

4). Automated Electronic Flow Control

Inlet flow ,packed column carrier flow and detector gas flow are all controlled by AEFC.

Stainless steel bonded plate

Imported micro proportional valve and flow/pressure sensor

Automatic temperature compensation ensure the accuracy of the flow.

Inlet pressure precision is 0.01psi.

Automatic shutdown function when hydrogen is leaked.

  

5).Valve Configuration  

Satisfying analytical need and application of different gases comprehensively

Automatic control and sequence running of valve drive

Imported VICI valve spool and AFP flush leak-free valve spool

Long-life and high-speed switching magnetic valve

High purity gas analysis specialized programme

Choose us! It's a sure way!