KT-906 THERMO-HYGROMETER-CLOCK-LIGHT
Characteristic:
1. 3 line of LCD display.Show the indoor temperature/humidity ,time and date at the same time.
2. Night light function,more convenient for people to use the product at night.
3.Weather forecast function, according to real-time changes in temperature and humidity values to predict the weather.
4.Alarm function. And 12/24 hour display switching function
5."°C / °F" switching function, can choose to display °C or °F.
6. Highest / lowest indoor temperature and humidity memory function.
7.Products with Supporting plate and hanging hole ,can be placed in vertical or hanging
Temperature survey range:: 0°C-50°C(32°F-122°F)
Humidity survey range : 10%- 98%
Analyze degree: 0.1°C, 1%RH
Accurate precision: ±1°C, ±5%RH
Power Supply: one AAA battery
The button usage
* "MODE"
1 , press once to switch the display time and set the alarm time ( two dots without flashing , and with an "AL" prompt in the upper right corner ) .
2 ,Time and Date setting
When displaying the time mode, press and hold 2 seconds to enter time setting , set the minute, hour, 12/24 hour mode , month, day . During the time digits flash , press "ADJ" to adjust. When completed a set , and then press the "MODE" key once , the next one will be automatically set . If one minute without any key operation , it will automatically exit setup,and finish setting.
3 ,Alarm setting
When displaying the alarm time (AL) mode , press and hold 2 seconds to enter the alarm time setting , the same operation mode and time settings .
* "ADJ"
1,When setting time , date, alarm, you can make the data increases, Press and hold the button to increase rapidly.
2 , When displaying the alarm time (AL) mode , press the ADJ adjustable alarm off. ( When Alarm function is turned on, the screen has a bell icon in the upper right corner ) .
* "MAX / MIN"
1 , Press "MAX / MIN" key once to display the maximum period of MAX- measuring indoor temperature and humidity ; then press the "MAX / MIN" key once to display the minimum measurement period MIN- indoor temperature and humidity .
* "C / F"
1 , press "°C / °F" key, you can choose to display temperature in Celsius or Fahrenheit .
* "LIGHT"
1 , press "LIGHT" button, the screen will be bright blue backlight for 3 seconds .
* Precautions:
1 , when there is not legible , for the battery needs to be replaced with new batteries.
2 , reinstall the battery, time, date , alarm clock and other functions need to re- set , the last high / low temperature and humidity memory is also cleared .