| Place of Origin: | China (Mainland) |
|---|---|
| Brand Name: | ANSUN |
| Model Number: | AS12D |
| nominal working voltage: | 12V |
| nominal discharge current: | 3KA |
| max discharge current: | 5KA |
| protection level: | 25V |
| response time: | 1ns |
| transmission speed: | 1.5Gbps |
| interface type: | BNC |
Quick Details
Specifications
ANSUN latest product: single channel HD-SDI video surveillance SPD is widely used to protect HD surveillance system in government project. New model 3G-SDI video signal SPD is in R&D phase.
Safety precautions:
a) When SPD is installed in final system, it must achieve all the requirements of GB4943 (EN60950, IEC60950) standard;
b) The equipment has to be installed by authorized professional person, to avoid incorrect installation or application to influence the normal working and lightning protection of devices
Application
Mainly used in HD-SDI HD camera video signal device point to point protection, to protect various video transmission device from being damaged by indirect lightning and surge voltage of signal transmission line.
Feature
1) Low insertion loss, quick response
2) Precise limiting voltage, high discharger current capacity
3) Stable performance, reliable work
4) Easy installation
Specification
|
Model |
AS12D |
|
Nominal working voltage Un |
12V |
|
Nominal discharge current(kA) |
3KA |
|
Max discharge current(kA) |
5kA |
|
Protection level(Up) |
≤25V |
|
Response time |
1 ns |
|
Transmission rate |
1.5Gbps |
|
Insertion loss |
≤0.2 dB |
|
Interface type |
BNC |
|
Protection channel |
1 |
|
Protection Level |
IP20 |
|
Installation |
series |
|
Working conditions |
Temperature:-40~+85℃; Relative humidity:≤95%(25℃); Elevation≤3km |
|
Note: For latest information, please contact ANSUN company |
|
Installation and wiring
a) HD-SDI camera SPD is connected by series between protected devices and signal path
b) The closer the distance between SPD and protected device, the better the effect
c) To connect ground line of SPD to lightning protection system ground device, lower connecting wire is better, within 1m