Product Main

Quick Details

Place of Origin: China (Mainland)
Brand Name: BABI
Model Number: F56
Medium: Liquids, gases, vapors
Straight unimpeded inlet run: >=5D
Straight unimpeded outlet run: >=250 mm
Degree of protection: IP67(Others need specify in the order)
Carried Standard: JB/T 6844-93
Rated voltage: 8 V DC
Contact form: SPST
Power rating: 10W
Switching current(Max.): 1.0A
Load current(Max.): 1.5A
Switching voltage(Max.): 100V
Min. breakdown voltage: 200V
Contact impedance: 200 milliohms
Insulation impedance(min.): 1012ohms
Contact capacity (max.): 0.2pf
Power dissipation: 300mW
I/O isolation voltage: 1500V AC
Turn on time ( Max. ): 5ms
Turn off time* ( Max. ): 2ms

Specifications

5.2 Hygienic Clamp connection dimensions5.2 Hygienic Clamp connection dimensions 

1 General                            

F56 metal cone variable area flowmeters are used formeasure instantaneous and accumulated flow rate of liquid, gas and steam in closed pipelines. It is suitable for metering flow value on site orelectronic remote.  

The measuring principle is based on the hydrodynamic effects, This makes float moving from bottom to top in vertical Pipe. As the displacement of float is in related to flow rate, whichcan be

read from the indicator by means of the magnetic drive system in non-contact form . Also, flowmeters output electrical signal (4-20)mA / hart communication protocol with high / low limit Warning switches/integrating flow PCB broad can be configured.

 Features:

P8Mechanical indicator:

   Stainless steel housing , punch forming , surface finish.

   Machinery pointer indicatesflow valueon site.

   Lightly and beautiful appearance.

P10 Indicator:

   Modularization design, Exi, Exd explosion protection.

   2-wire electrical signal output (4-20)mA / hart communication protocol.

   Optional limit switches combination.

P10I indicator:

   Mechanical indicator with explosion protection housing.

   One or two limit switches are selectable.

P10B Indicator:

   P101 indicator with LCD display , power supply: 3.6V lithium battery

Typical applications:

Flow measuring and process control of Liquids, gases, vapors inpetroleum,

chemical industry , metallurgy , electric power , food processing industry,

pharmacy, papermaking, etc.

 2 Operating principle

F56 series variable area flowmeters is made up of flow sensor and flow indicator. Float is placed vertically inside ofconicalmeasuring tube and can freely move up and down along the conical tube owing to hydrodynamic effects.A high-performance permanent magnet is set inside float, by this way the magnetic

field around permanent magnet will change along with the float moving up and down.When fluid keeps a stable flow value and float locates in a dynamic balancestate in position, the magnetic field around permanent magnet keeps constant also.The magnetic signal will be transmitted in non-contact form by means of the flow Indicator mechanically connected to conical tube. In another word,the indicator is

able to detect and processflow value of liquid by magnetic drive system and finally the corresponding flow rate value can be read from the scale on site. Also it can indicate outputs as standardelectrical signal(4-20)mA / hart communication protocol.

Measurement of gases

2.1 When the valve is opened suddenly in pipeline or pressure is unstable during metering gases, airflow will be pulsating. As aresult, float moves up and down along the conical tube ceaselessly. In the meantime, system is out-of-control since pointer swinging constantly lead to output signal instability. In this conditions,damping device must be installed inside measuring tube (see fig.2-2). Thedamping

device become a self-centering damper of preventing block through special design and precision workofnumerical control machine centre. The damping device is consists of aluminum oxide ceramic(purity is 99.99%) and characterized by a long service life,resistant to corrosion, structure novelty, practicalitybetter.

 

3 Technical data

Type

F56

Medium

Liquids, gases, vapors

Rang(conversion to100%value of reference fluid )

Water : 20℃

(10-300000)L/h , Special orderon request:

Air : 0.1013MPa,20℃

(0.7-3000)Nm3/h, Special order on request:

The turn-down ratio

10 : 1

Accuracy class

Mechanical indicator

1.0, 1.5, 2.0, 2.5

Mechanical indicator with LCD(battery powered, service life: 2 years)

1.0, 1.5, 2.0, 2.5

Mechanical indicator with two-wire signal output (4-20)mA/hart communication protocol

1.0, 1.5, 2.0, 2.5

Medium temperature

Machinery indicator with LCD(battery powered, service life: 2 years)

-80℃~+300℃(PTFE:0~80℃)

High temperature 400℃

Mechanical indicator(battery powered, service life : 2 years)

-40℃~+120℃(PTFE:0~80℃)

High temperature 400℃

Mechanical indicator with two-wire signal output (4-20)mA/hart communication protocol

-40℃~+120℃(PTFE:0~80℃)

High temperature 400℃

Ambient temperature

Mechanical indicator

-40℃~+120℃

Mechanical indicator with LCD(battery powered, service life: 2 years)

-20℃~+60℃

Mechanical indicator with two-wire signal output (4-20)mA/hart communication

-20℃~+60℃

Viscosity of fluid

DN15: F15.00~F15.03  η<5 mPa.s,  F15.04~15.30  η<30 mPa.s;  DN25: η<250 mPa.s;  DN50~250: η<300 mPa.s

Nominal pressure

DN15~DN50

4.0MPa(Max DN15: 42MPa, DN25: 42MPa, DN50: 32MPa)

DN80~DN250

1.6MPa(Max DN80: 10MPa, DN100: 6.4MPa, DN125: 4.0MPa,

DN150: 4.0MPa, DN200: 2.5MPa, DN250: 2.5Mpa)

Process connection

Flange connection, Standard: DIN2501, ANSI, JIS(select Chinese standard freely, priority select DIN)  

Hygieneclamp, screw joint are selected in the order

Electrical connection

M20×1.5     1/2"G     1/2"NPT      3/4"G     3/4"NPT

Installation

Vertical mounting(bottom in up out and up in bottom out, Horizontal mounting(left in right out and right in left out)

bottom in side out, side in side out

Straight unimpeded inlet run

≥ 5D

Straight unimpeded outlet run

≥250 mm

Degree of protection

IP67(Others need specify in the order)

Exmarking

EEx ia II CT5

EEx d II CT6

Ex electrical data

Ui = 28V     Ii = 93mA     Pi = 0.65W    Ci ≤ 5nF     Li =0mH

Safety barrier data

Uo ≤ 28V     Io ≤ 93mA    Po0.65W    Co ≥ Ci+Cc  Lo ≥ Li+Lc

Carried Standard

JB/T  6844-93

 

4 Materials

Type

Measuring tube

Flange

Float

F56/PI, F56/UP

F56/HI, F56/BO

F56/SO

304/304SS, 304L/304LSS

316/316SS, 316L/316LSS

317/317SS, 317L/317LSS

304/304SS, 304L/304LSS

316/316SS, 316L/316LSS

317/317SS, 317L/317LSS

304/304SS, 304L/304LSS

316/316SS, 316L/316LSS

317/317SS, 317L/317LSS

Al, Ti

F56/SP

1Cr18Ni9Ti

With PTFEliner

1Cr18Ni9Ti

PTFE

Hastelloy-B1, B2, C4

Ti

F56/PV

PV

PV

PV

F56/PP

PP

PP

PP

F56/Ni

Hastelloy-B1, B2, C4

N6 

Hastelloy-B1, B2, C4

N6 

Hastelloy-B1, B2, C4

Ti N6

F56/Ti

Ti

Ti

Ti

Hastelloy-B1, B2, C4

F56/Zr

Zr

Zr

Zr

F56/Cu

Cu

F56/Al

Al

 Note: Hastelloy: nickel base alloy, PTPF:Teflon, Ti:titanium alloy

5Dimensions

5.1 Flange connection dimensions
5-1 Vertical mounting
5-2 Side in side outmounting
5-3 Bottom in side out mounting
5-4 Horizontal mounting
5-5 P8 mounting
Flange dimensions and table 

Nominal size

Flange dimensions (Standard :ANSI B 16.5 150  lbRF)

Nominal size/

pressure

Flange dimensions(Standard :DIN2501)

DN

D

k

d3

f

n

d2

DN/PN

D

k

d3

f

n

d2

1/2"

88.9

60.5

35.1

1.6

4

15.7

15/4.0

95

65

45

1.5

4

14

3/4"

98.6

69.9

42.9

1.6

4

15.7

20/4.0

105

75

55

1.5

4

14

1"

108.0

79.2

50.8

1.6

4

15.7

25/4.0

115

85

65

1.5

4

14

1-1/4"

117.3

88.9

63.5

1.6

4

15.7

32/4.0

140

100

76

1.5

4

18

1-1/2"

127.0

98.6

73.2

1.6

4

15.7

40/4.0

150

110

86

1.5

4

18

2"

152.4

120.7

91.9

1.6

4

19.1

50/4.0

165

125

100

2.0

4

18

2-1/2"

177.8

139.7

104.6

1.6

 4

19.1

65/1.6

185

145

120

2.0

4

18

3"

190.5

152.4

127.0

1.6

4

19.1

80/1.6

200

160

136

2.0

8

18

4"

228.6

190.5

157.2

1.6

8

19.1

100/1.6

220

180

156

2.0

8

18

5"

254.0

215.9

185.7

1.6

8

22.4

125/1.6

250

210

186

2.0

8

18

6"

279.4

241.3

215.9

1.6

8

22.4

150/1.6

285

240

212

2.0

8

22

8"

342.9

298.5

269.7

1.6

8

22.4

200/1.6

340

295

268

2.0

12

22

10"

406.4

362.0

323.9

1.6

12

25.4

250/1.6

405

355

320

2.0

12

26