| Place of Origin: | China (Mainland) |
|---|---|
| Brand Name: | BABI |
| Model Number: | F56 |
| Medium: | Liquids, gases, vapors |
| Straight unimpeded inlet run: | >=5D |
| Straight unimpeded outlet run: | >=250 mm |
| Degree of protection: | IP67(Others need specify in the order) |
| Carried Standard: | JB/T 6844-93 |
| Rated voltage: | 8 V DC |
| Contact form: | SPST |
| Power rating: | 10W |
| Switching current(Max.): | 1.0A |
| Load current(Max.): | 1.5A |
| Switching voltage(Max.): | 100V |
| Min. breakdown voltage: | 200V |
| Contact impedance: | 200 milliohms |
| Insulation impedance(min.): | 1012ohms |
| Contact capacity (max.): | 0.2pf |
| Power dissipation: | 300mW |
| I/O isolation voltage: | 1500V AC |
| Turn on time ( Max. ): | 5ms |
| Turn off time* ( Max. ): | 2ms |
Quick Details
Specifications
1 General
F56 metal cone variable area flowmeters are used formeasure instantaneous and accumulated flow rate of liquid, gas and steam in closed pipelines. It is suitable for metering flow value on site orelectronic remote.
The measuring principle is based on the hydrodynamic effects, This makes float moving from bottom to top in vertical Pipe. As the displacement of float is in related to flow rate, whichcan be
read from the indicator by means of the magnetic drive system in non-contact form . Also, flowmeters output electrical signal (4-20)mA / hart communication protocol with high / low limit Warning switches/integrating flow PCB broad can be configured.
Features:P8Mechanical indicator:
◆ Stainless steel housing , punch forming , surface finish.
◆ Machinery pointer indicatesflow valueon site.
◆ Lightly and beautiful appearance.
P10 Indicator:
◆ Modularization design, Exi, Exd explosion protection.
◆ 2-wire electrical signal output (4-20)mA / hart communication protocol.
◆ Optional limit switches combination.
P10I indicator:
◆ Mechanical indicator with explosion protection housing.
◆ One or two limit switches are selectable.
P10B Indicator:
◆ P101 indicator with LCD display , power supply: 3.6V lithium battery
Typical applications:
Flow measuring and process control of Liquids, gases, vapors inpetroleum,
chemical industry , metallurgy , electric power , food processing industry,
pharmacy, papermaking, etc.
2 Operating principleF56 series variable area flowmeters is made up of flow sensor and flow indicator. Float is placed vertically inside ofconicalmeasuring tube and can freely move up and down along the conical tube owing to hydrodynamic effects.A high-performance permanent magnet is set inside float, by this way the magnetic
field around permanent magnet will change along with the float moving up and down.When fluid keeps a stable flow value and float locates in a dynamic balancestate in position, the magnetic field around permanent magnet keeps constant also.The magnetic signal will be transmitted in non-contact form by means of the flow Indicator mechanically connected to conical tube. In another word,the indicator is
able to detect and processflow value of liquid by magnetic drive system and finally the corresponding flow rate value can be read from the scale on site. Also it can indicate outputs as standardelectrical signal(4-20)mA / hart communication protocol.
Measurement of gases
2.1 When the valve is opened suddenly in pipeline or pressure is unstable during metering gases, airflow will be pulsating. As aresult, float moves up and down along the conical tube ceaselessly. In the meantime, system is out-of-control since pointer swinging constantly lead to output signal instability. In this conditions,damping device must be installed inside measuring tube (see fig.2-2). Thedamping
device become a self-centering damper of preventing block through special design and precision workofnumerical control machine centre. The damping device is consists of aluminum oxide ceramic(purity is 99.99%) and characterized by a long service life,resistant to corrosion, structure novelty, practicalitybetter.
3 Technical data
|
Type |
F56 |
|||
|
Medium |
Liquids, gases, vapors |
|||
|
Rang(conversion to100%value of reference fluid ) |
Water : 20℃ |
(10-300000)L/h , Special orderon request: |
||
|
Air : 0.1013MPa,20℃ |
(0.7-3000)Nm3/h, Special order on request: |
|||
|
The turn-down ratio |
10 : 1 |
|||
|
Accuracy class |
Mechanical indicator |
1.0, 1.5, 2.0, 2.5 |
||
|
Mechanical indicator with LCD(battery powered, service life: 2 years) |
1.0, 1.5, 2.0, 2.5 |
|||
|
Mechanical indicator with two-wire signal output (4-20)mA/hart communication protocol |
1.0, 1.5, 2.0, 2.5 |
|||
|
Medium temperature |
Machinery indicator with LCD(battery powered, service life: 2 years) |
-80℃~+300℃(PTFE:0~80℃) High temperature 400℃ |
||
|
Mechanical indicator(battery powered, service life : 2 years) |
-40℃~+120℃(PTFE:0~80℃) High temperature 400℃ |
|||
|
Mechanical indicator with two-wire signal output (4-20)mA/hart communication protocol |
-40℃~+120℃(PTFE:0~80℃) High temperature 400℃ |
|||
|
Ambient temperature |
Mechanical indicator |
-40℃~+120℃ |
||
|
Mechanical indicator with LCD(battery powered, service life: 2 years) |
-20℃~+60℃ |
|||
|
Mechanical indicator with two-wire signal output (4-20)mA/hart communication |
-20℃~+60℃ |
|||
|
Viscosity of fluid |
DN15: F15.00~F15.03 η<5 mPa.s, F15.04~15.30 η<30 mPa.s; DN25: η<250 mPa.s; DN50~250: η<300 mPa.s |
|||
|
Nominal pressure |
DN15~DN50 |
4.0MPa(Max DN15: 42MPa, DN25: 42MPa, DN50: 32MPa) |
||
|
DN80~DN250 |
1.6MPa(Max DN80: 10MPa, DN100: 6.4MPa, DN125: 4.0MPa, DN150: 4.0MPa, DN200: 2.5MPa, DN250: 2.5Mpa) |
|||
|
Process connection |
Flange connection, Standard: DIN2501, ANSI, JIS(select Chinese standard freely, priority select DIN) |
|||
|
Hygieneclamp, screw joint are selected in the order |
||||
|
Electrical connection |
M20×1.5 1/2"G 1/2"NPT 3/4"G 3/4"NPT |
|||
|
Installation |
Vertical mounting(bottom in up out and up in bottom out, Horizontal mounting(left in right out and right in left out) bottom in side out, side in side out |
|||
|
Straight unimpeded inlet run |
≥ 5D |
|||
|
Straight unimpeded outlet run |
≥250 mm |
|||
|
Degree of protection |
IP67(Others need specify in the order) |
|||
|
Exmarking |
EEx ia II CT5 |
|||
|
EEx d II CT6 |
||||
|
Ex electrical data |
Ui = 28V Ii = 93mA Pi = 0.65W Ci ≤ 5nF Li =0mH |
|||
|
Safety barrier data |
Uo ≤ 28V Io ≤ 93mA Po ≤ 0.65W Co ≥ Ci+Cc Lo ≥ Li+Lc |
|||
|
Carried Standard |
JB/T 6844-93 |
|||
4 Materials
|
Type |
Measuring tube |
Flange |
Float |
|
F56/PI, F56/UP F56/HI, F56/BO F56/SO |
304/304SS, 304L/304LSS 316/316SS, 316L/316LSS 317/317SS, 317L/317LSS |
304/304SS, 304L/304LSS 316/316SS, 316L/316LSS 317/317SS, 317L/317LSS |
304/304SS, 304L/304LSS 316/316SS, 316L/316LSS 317/317SS, 317L/317LSS Al, Ti |
|
F56/SP |
1Cr18Ni9Ti With PTFEliner |
1Cr18Ni9Ti |
PTFE Hastelloy-B1, B2, C4 Ti |
|
F56/PV |
PV |
PV |
PV |
|
F56/PP |
PP |
PP |
PP |
|
F56/Ni |
Hastelloy-B1, B2, C4 N6 |
Hastelloy-B1, B2, C4 N6 |
Hastelloy-B1, B2, C4 Ti N6 |
|
F56/Ti |
Ti |
Ti |
Ti Hastelloy-B1, B2, C4 |
|
F56/Zr |
Zr |
Zr |
Zr |
|
F56/Cu |
Cu |
||
|
F56/Al |
Al |
5Dimensions
5.1 Flange connection dimensions
5-1 Vertical mounting
5-2 Side in side outmounting
5-3 Bottom in side out mounting
5-4 Horizontal mounting
5-5 P8 mounting
Flange dimensions and table
|
Nominal size |
Flange dimensions (Standard :ANSI B 16.5 150 lbRF) |
Nominal size/ pressure |
Flange dimensions(Standard :DIN2501) |
||||||||||
|
DN |
D |
k |
d3 |
f |
n |
d2 |
DN/PN |
D |
k |
d3 |
f |
n |
d2 |
|
1/2" |
88.9 |
60.5 |
35.1 |
1.6 |
4 |
15.7 |
15/4.0 |
95 |
65 |
45 |
1.5 |
4 |
14 |
|
3/4" |
98.6 |
69.9 |
42.9 |
1.6 |
4 |
15.7 |
20/4.0 |
105 |
75 |
55 |
1.5 |
4 |
14 |
|
1" |
108.0 |
79.2 |
50.8 |
1.6 |
4 |
15.7 |
25/4.0 |
115 |
85 |
65 |
1.5 |
4 |
14 |
|
1-1/4" |
117.3 |
88.9 |
63.5 |
1.6 |
4 |
15.7 |
32/4.0 |
140 |
100 |
76 |
1.5 |
4 |
18 |
|
1-1/2" |
127.0 |
98.6 |
73.2 |
1.6 |
4 |
15.7 |
40/4.0 |
150 |
110 |
86 |
1.5 |
4 |
18 |
|
2" |
152.4 |
120.7 |
91.9 |
1.6 |
4 |
19.1 |
50/4.0 |
165 |
125 |
100 |
2.0 |
4 |
18 |
|
2-1/2" |
177.8 |
139.7 |
104.6 |
1.6 |
4 |
19.1 |
65/1.6 |
185 |
145 |
120 |
2.0 |
4 |
18 |
|
3" |
190.5 |
152.4 |
127.0 |
1.6 |
4 |
19.1 |
80/1.6 |
200 |
160 |
136 |
2.0 |
8 |
18 |
|
4" |
228.6 |
190.5 |
157.2 |
1.6 |
8 |
19.1 |
100/1.6 |
220 |
180 |
156 |
2.0 |
8 |
18 |
|
5" |
254.0 |
215.9 |
185.7 |
1.6 |
8 |
22.4 |
125/1.6 |
250 |
210 |
186 |
2.0 |
8 |
18 |
|
6" |
279.4 |
241.3 |
215.9 |
1.6 |
8 |
22.4 |
150/1.6 |
285 |
240 |
212 |
2.0 |
8 |
22 |
|
8" |
342.9 |
298.5 |
269.7 |
1.6 |
8 |
22.4 |
200/1.6 |
340 |
295 |
268 |
2.0 |
12 |
22 |
|
10" |
406.4 |
362.0 |
323.9 |
1.6 |
12 |
25.4 |
250/1.6 |
405 |
355 |
320 |
2.0 |
12 |
26 |