| Place of Origin: | China (Mainland) |
|---|---|
| Brand Name: | SIHU |
| Model Number: | JDZ(F)11 - 35V |
| Usage: | |
| Phase: | Single |
| Coil Structure: | Toroidal |
| Coil Number: | |
| Insulated material: | Epoxy resin |
| Quality warranty: | 18 months |
| Rated output: | 60-200VA |
| Rated primary voltage: | 35kV |
| Dimensions: | 546x300x560(mm) |
| Colour: | Brown |
Quick Details
Specifications
Product Name: Single Phase VT 35kV
1 Instruction for JDZ(F)11 - 35V Voltage Transformer
The technical data and electric performance for the product all are the same as that of JDZ11-35 and JDZF11-35 VTs, but the terminals are marked as B and C for primary side and b and c for secondary side. To do so is very convenient and reliable for customers to matching 3 phase products in V connection.
2 Technical Parameters for Voltage Transformers
Technical Parameters Table
Notes:
1 The power factor can be 0.3~0.5(lag) according to the requirement from customers while class 0.2 needed. and cosΦ=0.8(lag) except for class 0.2. Rated output and relative accuracy classes only conform to the values in one among the three.
2 Detailed technical data and outline drawing shall be provided under request.
Application:
1.Power plant and power station.
2.All kinds of industrial area,such as factories,coal mine,subways and so on.
3.They also can be used in communities.
1 Instruction for JDZ(F)11 - 35V Voltage Transformer
The technical data and electric performance for the product all are the same as that of JDZ11-35 and JDZF11-35 VTs, but the terminals are marked as B and C for primary side and b and c for secondary side. To do so is very convenient and reliable for customers to matching 3 phase products in V connection.
2 Technical Parameters for Voltage Transformers
Technical Parameters Table
| Model | Rated Voltage (kV) | Accuracy Class | Rated Output (VA) | Limit Output (VA) | |
| Primary | Secondary | ||||
| JDZF11-35V | 35 | 0.1 | 0.2 |
60 |
1000 |
| 0.5 | 120 | ||||
| 1 | 200 | ||||
| JDZF11-35V | 35 |
1b-1c:0.1 2b-2c:0.1 |
0.2/0.2 | 25/25 | 500 |
| 0.2/0.5 | 30/30 | ||||
| 0.5/0.5 | 50/50 | ||||
1 The power factor can be 0.3~0.5(lag) according to the requirement from customers while class 0.2 needed. and cosΦ=0.8(lag) except for class 0.2. Rated output and relative accuracy classes only conform to the values in one among the three.
2 Detailed technical data and outline drawing shall be provided under request.
Application:
1.Power plant and power station.
2.All kinds of industrial area,such as factories,coal mine,subways and so on.
3.They also can be used in communities.