Place of Origin: | China (Mainland) |
---|---|
Brand Name: | |
Model Number: |
Quick Details
Specifications
GRI 8413 Portable Ozone(O3)Gas Detector
GRI 8413 Portable Ozone (electrochemical) gas detector is a kind of intellectual handheld alarm with high accuracy low consumption; detect the concentration of the toxic gas with advanced electrochemical technology in the target gases.
GRI-8413 series is natural diffused gas detection way, the sensitive component adopt the toxic gas sensors imported Switzerland Membrapor electrochemical, with very high sensitivity and excellent repeatability; with a LCD display screen, can on line observe the concentration value of the target gas; can check the time , Date and week, can output USB digital signal, communicate with monitor or PC; With two level alarm output, immediately start the light and sound alarm signal once exceed the preset point; with soft/hard two kind ways of calibration, can calibrate without off cap.
GRI-8413 series can be widely used in factory, office , warehouse, mine and other varies environment field for toxic gas detection.
Feature:
Switzerland electrochemical sensor, stable and reliable performance;
External power supply DC5V, build-in rechargeable 3.7V Lithium batteries, chargeable on communication;
Big screen LCD can display each parameter;
Can set and display time, date and week;
Intellectual design, full function, zero, alarm set, convenient for calibration;
Small shell can be put in the pocket or bag, hang on body, convenient for carry;
Two level light and sound alarm, 4 height light LED when the alarm mark the attention of users;
with one way USB digital signal output.
Parameter:
Product Name: Ozone Gas alarm detector
Sensor Name: Optional (electrochemical sensor)
Product Model: GRI-8413
Sensor Model: Optional (M series)
Battery Voltage: 3.7V (charge limit4.2V)
Object detection: Ozone Gas
Battery capacity: 600mAh
Detection principle: Electrochemical
Current consumption: 5-100mA
Detection method: Diffused
Display way: big LCD screen
Detection range : 0-5 ppm
Alarm way : Level light and sound alarm
Accuracy : ±5%FS
Alarm error : ≤±10% alarm setting value
Resolution : 0.1ppm
Operate temperature : -10℃to -50 ℃
Pre-warm time : 1 Min
Operate humidity: 0-95%RH
Responsible time: T90≤30S(Majority)
Voltage range : 860-1060hpa
Use life : 2 years (on the air)
Signal output: UART convert USB
Zero drift: ≤±2%FS/6h
Figure size: 102*60*35
Span drift: ≤±5%FS/6h
Machine weight: ≤100g
Responsibility: ≤±2%FS
Note: above part of sensor parameter please reference the technical manual of Membrapor of corresponding sensors