Place of Origin: | China (Mainland) |
---|---|
Brand Name: | CHIQI |
Model Number: | ZJ100 |
Electricity Type: | DC |
Number of Pole: | 2 |
Phase: | 1 |
Main Circuit Rating Voltage: | DC24V |
Main Circuit Rating Current: | 100a |
Contact form: | N.O |
packing: | 50pcs/ctn |
Delivery: | have stock ready,delivery at any time |
Quick Details
Specifications
DC Contactor
Application:
ZJ100A series DC contactor is suitable for the battery or the rectification power, using for handling drawing, the pump motor and other electronic vehicles. At the same time it has been widely used in communications power, UPS and other electronic control system
Brief Technical Data:
Application:
ZJ100A series DC contactor is suitable for the battery or the rectification power, using for handling drawing, the pump motor and other electronic vehicles. At the same time it has been widely used in communications power, UPS and other electronic control system
Brief Technical Data:
Number | Type and parameter | Coil and rated volt of contact circuit(v) | ||||||||
12 | 24 | 3 0 | 36 | 40 | 48 | 60 | 72 | 8 80 | ||
1 | Coil power dissipation < 15(w), Max. coil current(A) | 0.98 | 0.58 | 0.45 | 0.35 | 0.32 | 0.28 | 0.25 | 0.2 | 0.18 |
2 | main rated load current of contact circuitA) | Resistive load: て=1ms 100A Max. Rated working current of contact circuit for 4le, 5 seconds. | ||||||||
3 | voltage | 50Hz 1000V AC 1min | ||||||||
4 | Operating time | Pickup(contact makes): ≯30ms , release(contact breaks): ≯30ms | ||||||||
5 | Action characteristic | Release(contact breaks): ≯30%Us, ≮5%Us Pickup(contact) | ||||||||
6 | Mechanical life | 1 million times | ||||||||
7 | Electric life | Resistive load: 50000times, inductive load(DC-5): 60%le for Resistive load, 10000times | ||||||||
Notice: 1, Specifications subject to change as the custom request 2, Coil voltage in above 48V with permanent magnet blowouts |
Environmental condition:
1. Ambient temperature: -25~+40℃
2. Altitude range: 0~2000m
3. Max. relative humidity90% at 25℃
4. Vibration: 10~50Hz, 10m/s2
5. Shock: 30m/s2
6. Installation method: anywhere
7. Voltage fluctuating: 0.7~1.1Ue
8. Duty: 8h continuous
1. Ambient temperature: -25~+40℃
2. Altitude range: 0~2000m
3. Max. relative humidity90% at 25℃
4. Vibration: 10~50Hz, 10m/s2
5. Shock: 30m/s2
6. Installation method: anywhere
7. Voltage fluctuating: 0.7~1.1Ue
8. Duty: 8h continuous