Product Main

Quick Details

Place of Origin: China (Mainland)
Brand Name: XISHUN
Model Number: ZBW
Usage: JIW
Phase: Three Phase
Current Type: AC

Specifications

1.Product Introduction
ZBW Voltage optimizer is highly benificial when the electrictiy supply to the site is at a higher or lower voltage level than needed.
This system stabilizes the input voltage to be stable and generates a reliable ouput voltage to the residential,commercial
or industrial site.Therefore, it can achieve energy saving and electricity bill reduction by decreasing power consumption.
 
 
2.Technical Parameter
Power: 3KVA-50KVA ( single phase)
Single phase unit input & output voltage:
Input voltage:220V±20% (176-264V) or 220V±30% (154-286V) or larger range
Output voltage:220V±1% or 220V±2.5% (±1% to ±5% optional)
Capable to custom-make special input & output voltage
 
Power: 10KVA-2000KVA ( three phase)
Three phase unit input voltage & output voltage:
Input voltage:380V±20% (304-456V) or 380V±30% (266-494V) or larger range
Output voltage:380V±1% or 380V±2.5% (±1% to ±5% optional)
Capable to custom-make special input & output voltage
 
Working frequency:50Hz/60Hz
Center voltage(Set point):Can be set as per required
Regulation accuracy: (±1%-±5% ) optional
Response time: ≤10ms
Waveform distortion: Do not produce additional waveform distortion(static)
Efficiency: ≥98%
Delay output:First regulation, then output (protect equipment without shocks)
Function:default phase,over load,over current,over voltage,under voltage,short circuit and bypass protection.
 
3.Features&Benefits
Non-Contact/Brushless design
No relays
No contactors
No moving parts
Solid state high speed switching (microseconds) Silicon Controlled Rectifiers (SCR')
to suppress harmonics and facilitate the balancing of loads
Failsafe Electronic by-pass
High Purity (99.9%) electronically refined copper, first second, third windings
Cooling: With fan or without fan acceptable
99% typical efficiency with loadings from 15%-100%
All power passes through the voltage optimizer, which is connected downstream of the main switch and metering system of the main switchboard
Nippon Steel Z11 cold rolled grain oriented silicon electrical steel with low hysteresis
Extra function- Surge arrester inside to against the spikes
Extra function- Tempeature meter to show the temp. of the cabinet and inside components of the stabilizer
Extra function-Auto-manual bypass function-System automatically detect the malfuction, then go to bypass, this is called auto bypass; install a bypas switch ( isolator) inside is called manual bypass.
Extra function-Digital panel control automatically monitor temperature, input voltage conditions, L1-L2-L3 and output pre-set L1-L2-L3 stabilized readings, output voltage(per line) can be independently 'fine tuned' from within front of cabinet
Extra function-Online/On-load 'Real Time' internet monitoring of power distribution system via RS-485 communication port via a web accessable Accuvin 11 high precision multifunction data logger