Product Main

Quick Details

Place of Origin: China (Mainland)
Brand Name: Qinwei
Model Number: HL-LWS
Measuring range ratio: 150
Explosion-proof mark: mdllBT4

Specifications

Specifications
1.Reliable performance,
2. high precision,
3. low power consumption,
4.Stable and reliable performance,

Intelligent electromagnetic flow meter consists of two parts of the sensor and converter. It is based on Faraday's law of electromagnetic induction work, is used to measure the conductivity is greater than 5μS/cm conductive liquid volume flow rate, is a measure of a conductive medium volume flow sensing instrument. In addition to general conductive liquid volume flow can be measured, can also be used to measure the volumetric flow rate of the strong acid and alkali and other strong corrosive liquids and slurries, pulp, pulp homogeneous liquid-solid two-phase suspension liquid.
Widely used in the industrial sector and the municipal administration of the petroleum, chemical, metallurgy, textile, papermaking, environmental protection, food, water conservancy construction, river dredging and other areas of flow measurement.

Pife lined pipe

10, 15, 20, 25, 32, 40, 50, 65, 80, 100, 125, 150, 200, 250, 300, 350, 400, 450, 500, 600

Rubber lined pipe

40, 50, 65, 80, 100, 125, 150, 200, 300, 350, 400, 500, 600, 800, 1000, 1200, note: special specifications can be customized

Flow direction

positive and negative, net flows Turndown

Measuring range ratio

150:1

Repeatability error

+/-0.1%

Accuracy

piped: 0.5 class, 1.0 class

Measured medium temperature

Common rubber lining: -20~+60 ° c

High temperature rubber lining: -20~+90 ° c

PTFE lining: -30~+100 ° c

High temperature vinyl lining: -30~+180 ° c

 

Rated working pressure

pipeline: DN10~DN65: ≤ 2.5MPa;DN80~DN150: ≤ 1.6MPa;

DN200~DN1200: ≤ 1.0MPa

Flow measuring range

flow measuring range corresponding to flow rate range is 0.3~15m/s

Measured fluid conductivity

5μs/cm (Most with water as the composition of the medium, its conductivity in the range 200~800 Mu s/cm, optional solenoid flow)

Output

current :4~20mADC (isolation), pulse frequency 0~1kHz, OCT photoelectric isolation, external power ≤ 35VDC, breakover, collector Max 25mA

Load resistance

< 600 Ω

Electrode material

316L, titanium (Ti), tantalum (Ta), Hastelloy, (h), Platinum (Pt) or other special electrode materials

Protection grade

standard: IP65; IP68

Working power supply

85~265VAC 45~63HZ

Straight pipe length

pipe: ≥ 5DN in the upper reaches, downstream of greater than or equal to 2DN

Connections

flow meter connected to the piping is used between flanges, flange connection dimensions comply with GB9119-88 requirements.

Explosion-proof mark

mdllBT4

environment temperature

-25 ° c ~=60 ° c

Relative humidity

5%~95%

Total power consumption

<20W