Place of Origin: | China (Mainland) |
---|---|
Brand Name: | Qinwei |
Model Number: | HL-LWS |
Measuring range ratio: | 150 |
Explosion-proof mark: | mdllBT4 |
Quick Details
Specifications
2. high precision,
3. low power consumption,
4.Stable and reliable performance,
Intelligent electromagnetic flow meter consists of two parts of the sensor and converter. It is based on Faraday's law of electromagnetic induction work, is used to measure the conductivity is greater than 5μS/cm conductive liquid volume flow rate, is a measure of a conductive medium volume flow sensing instrument. In addition to general conductive liquid volume flow can be measured, can also be used to measure the volumetric flow rate of the strong acid and alkali and other strong corrosive liquids and slurries, pulp, pulp homogeneous liquid-solid two-phase suspension liquid.
Pife lined pipe
10, 15, 20, 25, 32, 40, 50, 65, 80, 100, 125, 150, 200, 250, 300, 350, 400, 450, 500, 600
Rubber lined pipe
40, 50, 65, 80, 100, 125, 150, 200, 300, 350, 400, 500, 600, 800, 1000, 1200, note: special specifications can be customized
Flow direction
positive and negative, net flows Turndown
Measuring range ratio
150:1
Repeatability error
+/-0.1%
Accuracy
piped: 0.5 class, 1.0 class
Measured medium temperature
Common rubber lining: -20~+60 ° c
High temperature rubber lining: -20~+90 ° c
PTFE lining: -30~+100 ° c
High temperature vinyl lining: -30~+180 ° c
Rated working pressure
pipeline: DN10~DN65: ≤ 2.5MPa;DN80~DN150: ≤ 1.6MPa;
DN200~DN1200: ≤ 1.0MPa
Flow measuring range
flow measuring range corresponding to flow rate range is 0.3~15m/s
Measured fluid conductivity
5μs/cm (Most with water as the composition of the medium, its conductivity in the range 200~800 Mu s/cm, optional solenoid flow)
Output
current :4~20mADC (isolation), pulse frequency 0~1kHz, OCT photoelectric isolation, external power ≤ 35VDC, breakover, collector Max 25mA
Load resistance
< 600 Ω
Electrode material
316L, titanium (Ti), tantalum (Ta), Hastelloy, (h), Platinum (Pt) or other special electrode materials
Protection grade
standard: IP65; IP68
Working power supply
85~265VAC 45~63HZ
Straight pipe length
pipe: ≥ 5DN in the upper reaches, downstream of greater than or equal to 2DN
Connections
flow meter connected to the piping is used between flanges, flange connection dimensions comply with GB9119-88 requirements.
Explosion-proof mark
mdllBT4
environment temperature
-25 ° c ~=60 ° c
Relative humidity
5%~95%
Total power consumption
<20W
Widely used in the industrial sector and the municipal administration of the petroleum, chemical, metallurgy, textile, papermaking, environmental protection, food, water conservancy construction, river dredging and other areas of flow measurement.