Product Main

Quick Details

Place of Origin: China (Mainland)
Brand Name: Qinwei
Model Number: HL-LWS

Specifications

Specifications
1, corrosion and rust steel for the health sector;
2, easy installation and maintenance;
3, high accuracy, good repeatability;

vortex flowmeter has little pressure loss, broad span range and high accuracy. It is not under influence of density, pressure, temperature and viscocity when measuring volumetric flow. It has no movable mechanical parts with high reliability and little maintenance.

 

 

 

Parameter of vortex flow meter

 
 

Measured Mediums

liquids, gases and steams (NOTE: the mediums should be unidirectional or can be seen as unidirectional.)

 

When the dryness of saturated steams ≥85%, they can be seen as unidirectional.

 

Temperature of Mediums

- 40°C ~ + 350°C

 

Pressure of Mediums

1.6MPa, 2.5MPa, 4.0 MPa

 

For over 4.0 MPa, please contact us freely, for it needs special customization.

 

Accuracy

1.0; 1.5

 

Span Rate

1:8 ~ 1:30(compared with the standard atmospheric pressure)

 

1:8 ~ 1:40 ( compared with the nominal temperature water)

 

Flow Range

Liquids: 0.4 ~ 7.0 m/s

 

Gases: 4.0 ~ 60.0 m/s

 

Steams: 5.0 ~ 70.0 m/s

 

Nominal Diameter

DN 25, 40, 50, 65, 80, 100, 125, 150, 200, 250,300 mm

 

Materials

1Cr18Ni9Ti

 

Reynolds No.

Normally, 2*104 ~ 7*106

 

Resistance Coefficient

Cd ≤ 2.6

 

Licensed Vibration Acceleration

LUGB type ≤ 0.2g

 

Class of Protection

IP65

 

Class of Explosion-Proof

Intrinsically Safe Explosion-Proof: Exia II CT2 ~ CT6

 

Explosion Suppression: Exid II CT4

 

Conditions of Surroundings

Temperature of Surroundings:

Non-Explosion Proof Surroundings: -40°C~ +55°C

 

Explosion-Proof Surroundings: -20°C~ +55°C

 

Relative Humidity:

≤ 85%

 

Atmospheric Pressure:

86 ~ 106 kPa

 

Power Supply

Non-Explosion Proof Type

Pulse type:

+12 VDC ( the output current is 4 ~ 20mA)

 

Current type:

+24 VDC ( the output current is 4~ 20mA)

 

Explosion-Proof Type

Current type:

+24 VDC ( the output current is 4~20mA)

 

Output Signal

Frequency pulse signal 2~3000Hz, low level voltage ≤1V, high level voltage ≥ 6V

 

Two-wire system 4 ~ 20mA signal (isolation output), load ≤ 500Ω.

 

           

 

 

 

 

Measure range of vortex flow meter

Diameter (mm)

Water

Gases in the Normal Temperature and Pressure

Range of Standard Measurement (m3/h)

Range of Standard Measurement (m3/h)

  25

  2 ~ 16

  8~60

  32

  1.5~15

  14~100

  40

  3~30

  18~180

  50

  4~40

  30~300

  65

  6~60

  50~500

  80

  13~130

  70~700

  100

  20~200

  100~1000

  125

  36~360

  150~1500

  150

  50~500

  200~2000

  200

  100~1000

  400~4000

  250

  150~1500

  600~6000

  300

  200~2000

  1000~10000