GVS9-24 Series Embedded Poles Type High Voltage Vacuum Circuit Breaker
GVS9-24 series embedded poles type high voltage vacuum circuit breaker apply for rated voltage 24Kv, frequency 50Hz three-phase AC power system, widely used in power plants, substations, petrochemical, metallurgical, manufacturing, airports and communities, use for electrical facilities' protection and control, especially for frequency operating under the rated current or more time for short-circuit interrupting the place. With the VD4, VEP circuit breaker full realization of interchangeable, can be installed on away-style or fixed air-insulated switchgear cabinet. The product accordance to GB1984 " AC high voltage circuit breaker" , DL/T403 " 12~40.5Kv indoor AC high-voltage circuit breaker order technical condition" ; and IEC60694, IEC6227-100 and other related standards.
GVS9-24 series embedded poles type high voltage vacuum circuit breaker adapt to APG advanced technology, directly to put the vacuum interrupter room and lead electrical circuit solid seal in epoxy resin post then become the way of solid sealing insulation, represents the highest level of the design and manufacture of high voltage vacuum circuit breaker today world.
Note: this models vacuum circuit interrupter chamber seal replaced with ordinary insulation tube column installation method, the model GVS9-24P.
The Use of Environmental Conditions
1. Altitude: not exceed 2000m.
2. Ambient Temperature: not higher than +40 Celsius, not less than -15 Celsius.
3. Relative Humidity: daily average of not more than 95%, month average of not more than 90%.
4. Earthquake Intensity: not more than 8.
5. The ambient air without water drop, no fire, explosion hazard, serious filthy, chemical corrosion as well as place of intense vibration.
Mainly Technical Parameters NO. Item Units Value 1 Rated voltage kV 24 2 Rated frequency Hz 50 3 Rated lightning impulse voltage tolerance (peak) kV 125(fracture145) 4 Rated short-time power-frequency voltage tolerance (1min) kV 65(fracture79) 5 Rated current A 630, 1250 630, 1250 1250, 1600 2000, 2500 6 Rated short-circuit breaking current kA 20 25 31.5 7 Rated short-circuit closing current (peak) kA 50 63 80 8 Rated short-circuit duration time S 4 9 Rated operating sequence O-0.3-CO-180s-CO 10 Rated a single/ back-to-back electric current breaking device group A 630/400 11 Rated short-circuit breaking current breaking number Times 30 12 Closing time ms 35~70 13 Opening time ms 20~50 14 Mechanical life Times 10000 15 Rated storage and operation voltage V AC220/110DC220/110 16 Contact distance mm 13±1 17 Contact over travel mm 3.5±1 18 Average closing speed m/s 0.7~1.0 19 Average opening speed m/s 1.1~1.5 20 Contact closing spring time ms ≤2 21 Three phase closing opening asynchrony ms ≤2 22 Lead circuit resistance υΩ ≤50(630A)45(1250A)≤35(1600~2000A) ≤30(2500A) ≤25(3150A)