Place of Origin: | China (Mainland) |
---|---|
Brand Name: | ghorit |
Model Number: | GVM6-12 |
Type: | Magnetic |
Poles Number: | 3 |
certificate: | ISO9002 |
rated voltage: | 12kv |
rated frequency: | 50hz |
Quick Details
Specifications
GVM6-12 series permanent magnet embedded poles type indoor vacuum circuit breaker is a three-phase AC 50Hz, rated voltage of 12kV indoor switchgear. I loaded the company with its own research and development of permanent magnetic actuator for industrial and mining enterprises, power generation and substation facilities as electrical control and protection purpose. The product has high reliability and long life characteristics, especially suitable for frequent operation, repeatedly breaking conditions, such as short-circuit current of the place.
Note: this models vacuum interrupter chamber seal replaced with ordinary insulation tube column installation method, the model GVM6-12P.
Main Features
1.High reliability, long life, maintenance-free.
2. China's first permanent magnetic actuator mechanical life of up 100,000 times.
3.With the traditional actuator compared without mechanical removal, locking devices, parts and components significantly reduced the number of hours worked with only one moving parts, low failure rate.
4. Actuator performance and interrupter breaking. Closing the features needed for a very consistent.
5. All sub-reliable operation of the bistable gate.
6.With anti-skip function.
7. With controlling power low-voltage alarm refuse to close
8.Mechanical manual sub-sub-gate and electric gate at the same rate, in the secondary power supply fault conditions, the application of an emergency sub-gate.
9. AC and DC energy storage operation type, operating current is less than 2A, can be done o-co-o operation within 2 hours after the blackout.
10. Highly reliable operation of control circuit module that can be tolerated in the run-time lighting, surge and other harsh conditions.
11. Versatility, installation size and ZN63 VS1 compatible with other products.
The Use of Environmental Conditions
1. Ambient Temperature: not higher than +40 Celsius, not less than -25 Celsius.
2. Altitude: not exceed 1000m, plateau type not exceed 3000m.
3. Relative Humidity: daily average is not more than 95%, month average is not more than 90%, statured vapor pressure daily average is not more than 2.2x10-3 MPa, month average is not more that 1.8x10-3 MPa. The temperature dropped rapidly during the period of high humidity is that it may gel.
4. Earthquake Intensity: not more than 8.
5. No fire, explosion hazard, serious filthy, chemical corrosion, as well as places of intense vibration.
Mainly Technical Parameters NO. Item Units Parameters 1 Rated voltage kV 12 2 Rated insulation level 1 min frequency voltage 75 Rated lightning impulse voltage tolerance 42 3 Rated current A 630-1250 1250-3150 1250-4000* 4 Rated short-circuit breaking current kA 20 31.5 40 5 Rated short-circuit closing current (peak) 50 80 100 6 Dynamic stability rated current (peak) 50 80 100 7 Rated thermal stability of current (RMS) 20 51.5 40 8 Rated short-circuit breaking current breaking number Times 30 30 20 9 Rated thermal stabilization time S 4 10 Rated operating sequence O-0.3s-CO-180s-CO 11 Mechanical life Times ≥5000≥5000≥3000** 12 Permanent magnetic actuator and transmission part of the mechanical life Times ≥100000≥100000≥100000 13 Rated single capacitor breaking current A 630 14 Rated back to back capacitor breaking current 400 15 Rated breaking current-step kA 12.6 16
*There should be greater than the rated current 3150A ventilation measures.
**According to the chosen vacuum interrupter and the disparity.
Adjust the Parameters of Mechanical Properties NO. Item Units Parameters 1 Contact distance mm 11±1* 2 Contact travel 3.5±0.5 3 Three phase opening synchronism ms ≤2 4 Contact closing spring time ≤2 ≤3(40kA) 5 Phases center distance mm 210 275 6 Closing contact pressure N 20Ka 31.5kA 40kA 2000±200 3100±200 4500±300 7 Leading electrical circuit resistance υΩ 60 45 30 8 Average opening speed m/s 1.1±0.2 9 Average closing speed 0.7±0.2 0.8±0.2 10 Opening time ms 30~60 11 Closing time 50~100 12 Action static contact cumulative wear thickness allows mm 3