Product Main

Quick Details

Place of Origin: China (Mainland)
Brand Name: KCCV
Model Number:

Specifications

Specifications
1.Rangable 15:1(max. 40:1) 
2.4~20mA analog output signal with HART PROTOCOL 
3.Based on Metal Capacitive sensor technologies
Based on metal capacitive technology, Capacitive Differential Pressure Transmittersis designed by using imported key raw material & parts, and its performances & outward appearance achieve international advanced level. It is suitable for the measurement and control of different pressure, gauge pressure, level etc. It is also can be used for measuring corrosive medium or used in hard & dangerous working environment, can satisfy customer's request in max. limit.
Capacitive Differential Pressure Transmitters feature wide measuring pressure ranges, high accuracy, good long term stability, excellent performance as well as many structures. Thanks to the integrate electronics, the standard output (4~20mA) of UIB3351 can be iterated digital communication signal(HART Protocol), but without interrupting the signal sending out to control systems. The control room can carry on long-distance inquiry to transmitters or make configuration again.
Capacitive Differential Pressure Transmitters is widely used in technical areas such as petroleum industry, chemical industry, steel and iron industry, electric power, food, papermaking industry, spinning and weaving, medicine and environmental protection and so on.

Features
1. Excellent measuring performance, suitable for measurement of differential pressure, gauge pressure, absolute pressure, level and fluid.
2. Rangable 15:1(max. 40:1)
3. 4~20mA analog output signal with HART PROTOCOL, can realize long-distance operation
4. Intrinsic safety(Exia II CT6), optional flame-proof(Exd II CT6)
5. Protection:IP67

Specifications


pressure medium

gas liquid and steam

pressure ranges

0~0.1kPa...10MPa D
0~1kPa...40MPa G
0~6kPa...10MPa A

pressure type

gauge(G),absolute(A),differential (D)

system pressure

40bar/100bar/250bar/320bar

output signal

4~20mA(HART protocol option)

accuracy

0.1%FS , 0.2%FS, 0.5%FS

system pressure effect

0.2%FS/10MPa(can be modified under pipeline)

load resistance

RL = (U-12V)/0.02A U-power supply voltage (V DC)

long term stability

<0.2%FS/year

supply voltage

12~45V

operating temperature range

-40~+85°c, (-20~+65°c with indicator)

media temperature range

-40~+120°c

storage temperature range

-40~+105°c

temperature coefficient of zero

0.03%FS/10°c

temperature coefficient of span

0.03%FS/10°c

insulation resistance

100MΩ @ 50VDC

process connection

1/4"NPT

electrical connection

M20×1.5 or 1/2NPT

meter

0~100% linear meter ot 3-1/2 digital meter

sensor filled oil

silicon oil, fluorocarbon oil

o-ring

butyronitrile rubber, fluorine rubber, polytetrafluoro, metal sealing ring etc

Electronic shell and coating

low copper aluminum alloy, anodic oxidation, spray coating polyurethane

Electromagnetic/radio-frequency interference influence

20~1000MHz,output shift<0.01%FS for Field intensity of 30V/m

Vibration influence

on any axial,0.05%FS/g under 200Hz

Protection

IP67