Product Main

Quick Details

Place of Origin: China (Mainland)
Brand Name: KCCV
Model Number:

Specifications

Specifications
Suitable for electric power, metallurgy, chemical, water conservancy, foodstuff, sewerage treatment and boiler drum...
Advantages 
Multiple signal output modes adapt to different systems;
The sensing probe is made of Teflon to withstand acid and alkali etc. strong corrosive liquids (except for hydrofluoric acid and metal natrium) and high temperature;
Only a Teflon flexible wire or Teflon probe serves as sensor in measuring unit, so reliability is high;
Can applied to high temperature and high pressure occasion, and measuring value is not effected by temperature and specific gravity of measured liquids as well as shape and pressure of vessels;
2-wire LED local display, needn't power supply, drastically settled the question that LCD cannot display in dark environment;
Perfect over current, over voltage and reverse power polarity protection.
The main technical parameter 
1) Measuring range: 0.2~20m 
2) Accuracy:0.5%
3)Temperature of probe: -40~250 °C 4) Operating pressure:-1MPa~2.5MPa
5) Power supply: 24VDC
6) Output: 4~20mADC two-wire
7) Measure and adjustment range and zero elevation: ≥±30%FS
8) Measured medium: non-crystalline conductive liquids which conductivity is not less than 10-3s/m.