Product Main

Quick Details

Place of Origin: China (Mainland)
Brand Name: Kunlun
Model Number: KL-TC-80WM
Power: Electronic
Usage: Plastic Testing Machine
Color: Customize
Refrigerant: Environment-friendly R23/404a
Inner material: SUS#304 stainless steel plate
Temperature accuracy: 0.1 degrees Celsius
Control accuracy: around 2 degrees Celsius
Temperature fluctuation: around 2 degrees Celsius
Temperature uniformity: around 3 degrees Celsius
High temperature range: from 60 degrees Celsius to 200 degrees Celsius
Low temperature range: from -10 degrees Celsius to -80 degrees Celsius
Temperature recovery time Max: 5 minutes

Specifications

Temperature control test chamber

 

Product type:KL-TC-80WM(Air-cooled)

 

Detailed specification:

  1.High and low zone temperature range:

    high temperature range:60°C~ 180°C    low temperature range:-10°C~-55°C

  2.Temperature test zone:    

    high temperature zone:+60°C~ 150°C          low temperature zone:-10°C~-40°C

  3.Analytical accuracy:

    Temperature accuracy:0.1°C           Control accuracy:±2°C

    Temperature fluctuation:±2°C       Temperature uniformity:±3°C

  4.Regenerative district heating time:        RT ~ 120 °C (about 30 minutes)

  5.Storage area cooling time:                           RT ~ 50 °C (about 50minutes)

  6.Testing zone temperature recovery time:               5 minutes

  7.Mechanical structure:

     It is divided into three sections: the high temperature chamber, the low temperature chamber and the testing chamber.

  8.Inner material:                       SUS#304 cold-heat-resistant stainless steel;

  9.Testing basket size:              35cm×35cm×35cm (W×H×D)

  10.Voltage supply:              AC 220V±10%,50HZ   Max:55A

 

Product specifications:

 

1.Mechanical structure:

   A. The system meets the thermal cycling reliability test specifications (GJB150-2002, CNS, MIL, IEC, JIS). 

   B. Test samples are placed in the shelves and then the Japanese high torque linear motor drives the valve of the storage area to guide air circulation, meeting the purpose of testing the average temperature in the cold and heat temperature test.

   C. Special design is adopted by thermal shock chamber to save space and get moderate operate altitude. So it is easy for maintenance of thermal shock chamber.

   D. The insulating layer consists of anti-fire PU and high density fiber cotton to acquire best performance. In addition, the new design of K-type anti-sweat duct system is used to make the instrument more precise.

   E. Two groups of adjustable stainless steel shelves is available in the test area.

   F. High load pulleys are installed in the bottom of the machine to facilitate the movement of the machine.

   G High-cold-resistant stainless steel has the ability of high tightness even in the serious temperature conditions.

 

2.Refrigeration and temperature control system:

   A. It is equipped with the automatic and manual defrost system;

   B. U-type fin-speed heater;              

   C. K-type inner spiral refrigerant copper tube;

   D. A France Tecumseh high-efficiency and low-noise compressor;

   E. Slope type Fin-tube evaporator;

   F. Original imported electromagnetic valve, dry filter, capillary and other frozen components;

   G. Water-cooled condenser;

   H. A high quality and environmental protection R404a/R23 refrigerant;

   I. A France Tecumseh semi-hermitic compressor is adopted in the refrigeration system to acquire binary refrigerating and rapid effect.

   J. The multi-wing circulating fan is adopted in the storage area to improve the average temperature efficiency by forcing air flow.

   K. P.I.D and SSR microcomputer are used in the hot-and-cold area and the test area to make automatic calculation of high control precision for temperature control

 

3.Air circulation system and drainage system:

   A. The drainage system adopts the volute drainage and U-TRAP deposition apparatus.

   B. Multi-wing centrifugal circulating fan is connected to the power saving motor made in Japan through the stainless steel long axis.

   C. Air supply: horizontal diffusion curved vertical heat exchange loop.

 

4.Description of control system:

   A. Automatic circulation shock and manual selective shock are all available in this system.

   B. The color touch screen is used in the controller for convenience setting and microcomputer SSR used for automatic temperature control.

   C. Two area or three area shock are all available as well as forward or reverse start.

   D. Maximum cycle up to 9999 times;

   E. If the instrument fails to work, the instrument will be shut down automatically with warning signals.

   F. If you wants to set high or low temperature individually, time control up to 999H59M is available.

 

5. Security protection system:

   A. It is equipped with no fuse protection switch.

   B. Under-voltage protection and translation protection are available in the control system.

   C. There is a over-temperature protection switch.

   D. Overload protection device and high-and-low pressure protection switch are equipped in the refrigeration compressor.

   E. The fan motor and air-duct gate motor are also in the overload protection.

   F. The instrument is equipped with the self-detection function to find the failure point for easy maintenance.

 

 

Our company:

 

    Kunlun instrument (China) limited,was founded in 2000 years,our factory in Dongguan City Guangdong Province,is a high-tech enterprise that specified in develop and manufacuring all kinds of testing machine.More than 10 years,Kunlun always insisted on the road  of independent innovation and R&D. By virtue of the leading product technology and perfect quality system, good    quality services and productions meeting ASTM, JIS, ISO, IEC, UL, GB and other standards.

 

The trade show: