Product Main

Quick Details

Place of Origin: United States
Brand Name: FOXBORO
Model Number:

Specifications

FBM201
 Channel Isolated, 8 Input 0-20 mA
 Analog input
 Conversion time, rate of change limits
 PSS 21H-2Z1 B4
 
FBM202
 Channel Isolated, 8 Input Thermocouple/mV
 Analog input
 Conversion time, rate of change limits
 PSS 21H-2Z2 B4
 
FBM203
 Channel Isolated, 8 Input RTD(Platinum, Nickel, Copper)
 Analog input
 Conversion time, rate of change limits
 PSS 21H-2Z3 B4
 
FBM204
 Channel Isolated, 4 Channel 0-20mA In + 4 Channel 0-20mA Out
 Analog I/O
 Conversion Time, Fail-Safe Configuration(Hold/ Fallback on per channel  basis)
 PSS 21H-2Z4 B4
 
FBM205
 Channel Isolated, 4 Channel Redundant 0-20mA In + 4 Channel Redundant 0-20mA Out
 Analog I/O
 Conversion Time, Fail-Safe Configuration(Hold/ Fallback on per channel  basis)
 PSS 21H 2Z5 B4
 
FBM207
 Channel Isolated, 16 DIN Voltage Monitor
 Discrete I/O
 Input filter time
 PSS 21H-2Z7 B4
 
FBM207b
 Channel Isolated, 16 DIN 24VDC Contact Sense
 Discrete I/O, or ladder logic
 Input filter time
 PSS 21H-2Z7 B4
 
FBM207c
 Channel Isolated, 16 DIN 48 VDC Contact Sense
 Discrete I/O, or ladder logic
 Input filter time
 PSS 21H-2Z7 B4
 
FBM213
 Group Isolated, 8 Input RTD
 Analog input
 Conversion time, rate of change limits
 PSS 21H-2Z13 B4
 
FBM214
 8 Input Hart Communication, 4-20mA input signal
 Analog input
 Support for the HART commands necessary to interface the field device with the I/A series system database
 PSS 21H-2Z12 B4
 
FBM216
 Redundant Ready HART Inputs, 8 Channels
 
 
 
 
FBM217
 Group Isolated, 32 Discrete Input
 Discrete I/O, or ladder logic
 Input Filter Time
 PSS 21H-2Z17 B4
 
FBM219
 Discrete I/O, 32 Channels, 24 DIN voltage monitor+8 DOUT pulse, group isolated
 Discrete I/O, or ladder logic
 Input filter time, Fail-Safe Configuration, Fail-Safe fallback, Sustained and Momentary output. If momentary output configurable is needed, pulse output interval can be also configurable.
 PSS 21H-2Z19 B4
 
FBM211
 Differential Isolated, 16 differential Input 0-20 mA
 Analog input
 Conversion time, rate of change limits
 PSS 21H-2Z11 B4
 
FBM224
 4 Modbus Communication Channels
 
 Provides a interface between MODBUS salve devices and the Controller Process of I/A series system
 PSS 21H-2Z24 B4
 
FBM231
 Four Serial Ports, Redundant
 
 Provides a serial interface between dual-ported field I/O devices and I/A series system
 PSS 21H-2Z31 B4
 
FBM233
 10/100 Mbps Ethernet, Redundant
 
 
 PSS 21H-2Z33 B4
 
FBM237
 Channel isolated, 8 channel 0-20mA output, redundant
 Analog I/O
 Output Fail-Safe Configuration(Hold/ Fallback on per channel basis)
 PSS 21H-2Z37 B4
 
FBM241
 Channel Isolated, 8 channel voltage monitor, 8 channel DOUT pulse, external power
 Discrete I/O, or ladder logic
 Input filter time, Fail-Safe Configuration, Fail-Safe fallback, Sustained and Momentary output. If momentary output configurable is needed, pulse output interval can be also configurable.
 PSS 21H-2Z41 B4
 
FBM242
 Channel Isolated,16 External Source DO
 Discrete I/O, or ladder logic
 Fail-Safe Configuration
 PSS 21H-2Z42 B4
 
24 Port
 Fiber E'net Switch w/24 MT-RJ Ports & Uplink Ports
 
 Rapid scaling Tee Protocol(RSTR), manages redundant paths, prevent loops, and provides high speed convergence time for a network
 PSS 21H-7C3 B4