| Place of Origin: | China (Mainland) |
|---|---|
| Brand Name: | Haibao |
| Model Number: | HC-200 |
| Operating Principle: | Magnetic induction+whirlpool |
Quick Details
Specifications
1. Using both the magnetic and eddy current thickness method, as well as measuring the thickness of the magnetic non-magnetic coating on metal substrates can measure the non-magnetic again the thickness of the conductive coating on metal substrates;
2. With two measurement methods: continuous measurement methods (pieces CONTIN E) and word measurement mode (SINGLE);
3. With two works:direct mode(Direct) and burst mode(App1);
4. With five statistics:MEAN,MAX,MIN,NO,S.DEV;
5. Two methods can be used together for calibration, basic calibration method and can be used to modify the system error of measuring head;
6. With functions of storage:in storage 500 observed value;
7. Delete function: in the measurement of single suspicious data to delete, can also delete all data storage area for the new measurement;
8. Can be set limits:the measured value beyond the limit alarm automatically; And can be used histogram analysis of a batch of measurements;
9. Have print function: can print measurement, statistics, limit, histogram;
10. Can have a communication with a PC with: measurement, statistics can be transfer to the PC, so that the data for further processing;
11. With functions of power supply undervoltage instruction;
12. Operating projects hum tips;
13. Have error function, through the screen or hum errors;
14. two kinds of shutdown mode: Manual shutdown mode and automatic shutdown mode;
15. Dimension: 140×65×30mm
16. Weight: 0.2kg
2. With two measurement methods: continuous measurement methods (pieces CONTIN E) and word measurement mode (SINGLE);
3. With two works:direct mode(Direct) and burst mode(App1);
4. With five statistics:MEAN,MAX,MIN,NO,S.DEV;
5. Two methods can be used together for calibration, basic calibration method and can be used to modify the system error of measuring head;
6. With functions of storage:in storage 500 observed value;
7. Delete function: in the measurement of single suspicious data to delete, can also delete all data storage area for the new measurement;
8. Can be set limits:the measured value beyond the limit alarm automatically; And can be used histogram analysis of a batch of measurements;
9. Have print function: can print measurement, statistics, limit, histogram;
10. Can have a communication with a PC with: measurement, statistics can be transfer to the PC, so that the data for further processing;
11. With functions of power supply undervoltage instruction;
12. Operating projects hum tips;
13. Have error function, through the screen or hum errors;
14. two kinds of shutdown mode: Manual shutdown mode and automatic shutdown mode;
15. Dimension: 140×65×30mm
16. Weight: 0.2kg