Model
|
HS-350-5
|
HS-350-12
|
HS-350-15
|
HS-350-24
|
HS-350-27
|
HS-350-48
|
output
|
DC voltage
|
5V
|
12V
|
15V
|
24V
|
27V
|
48V
|
Voltage tolerance
|
±2%
|
±1%
|
±1%
|
±1%
|
±1%
|
±1%
|
Rated current
|
50A
|
29A
|
23A
|
14.6A
|
13
|
7.3
|
Current range
|
0~50A
|
0~29A
|
0~23A
|
0~14.6A
|
0~13A
|
0~5.2A
|
Rated power
|
250W
|
348W
|
345W
|
350.4W
|
351W
|
350.4W
|
Ripple&noise
|
150mvp-p
|
150mvp-p
|
150mvp-p
|
180mvp-p
|
180mvp-p
|
200mvp-p
|
DCvoltage ADJ.range
|
-9%~+10%
|
±10%
|
±10%
|
±10%
|
±10%
|
±10%
|
input
|
Voltage range
|
90~132VAC/180~264VAC(selected by switch), 255~373VDC
|
frequency
|
47~63HZ
|
AC current
|
6.5A/115VAC, 4.0A/230VAC
|
efficiency
|
80%
|
82%
|
82%
|
84%
|
84%
|
85%
|
Inrush current
|
Cold start current25A/115VAC, 50A/230VAC
|
Leakage current
|
< 3.5mA/240VAC
|
protection
|
overload
|
Rated output power110%~135% start over load protection
|
protection type:hiccup mode, auto-recovery after fault condition is removed
|
Over voltage
|
6.8~8.2V
|
15.6~17.8V
|
18.6~20.8V
|
30.6~33.2V
|
33.2~35.6V
|
54.8~56.6V
|
Protection type:hiccup mode, auto-recovery after fault condition is removed
|
Over temperature
|
TSW1detect on heatsink of power transistor≥85°C±5°C, start over temperature protection
|
protection type:hiccup mode, auto-recovery after temperature become normal
|
environment
|
Working temp,humidity
|
-10°C~+60°C, 20%~90%RH
|
Storage temp,humidity
|
-20°C~+85°C, 10%~95%RH non-condensing
|
Withstand vibration
|
10~500HZ, 2G 10min/1cycle, period for 60 minutes, each axes
|
safety
|
Withstand voltage
|
I/P-O/P:1.5KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
|
Isolation resistance
|
I/P-O/P,I/P-FG,O/P-FG:100Mohms/500VDC
|
Fit standard
|
Safety standard
|
Compliance to UL1012
|