Place of Origin: | China (Mainland) |
---|---|
Brand Name: | HD |
Model Number: | LPV-12W |
Output Power: | 1 - 50W |
Output Type: | Single |
Input Voltage: | 220V |
Output Voltage: | 12V/24V/48V |
Output Frequency: | 47-63Hz |
Output Current: |
Quick Details
Specifications
Model | LPV-12-12 | LPV-12-24 | LPV-12-36 | ------ | |
output | DC voltage | 12V | 24V | 36V | ------ |
Voltage tolerance | ±1% | ±1% | ±1% | ------ | |
Rated current | 1A | 0.5A | 0.33A | ------ | |
Current range | 0~1A | 0~0.5A | 0~0.33A | ------ | |
Rated power | 12W | 12W | 11.9W | ------ | |
Ripple&noise | 120mvp-p | 150mvp-p | 150mvp-p | ------ | |
input | Voltage range | 170~264VAC, 235~373VDC | |||
Frequency | 47~63HZ | ||||
AC current | 0.1A/230VAC | ||||
Efficiency | 78% | 80% | 82% | ------ | |
Inrush current | Cold start current 30A/230VAC | ||||
Leakage current | <0.5mA/240VAC | ||||
protection | Over load | Rated output power 105%~135%start over load protection | |||
Protection type:hiccup mode, auto-recovery after fault condition is removed | |||||
Over voltage | 15.6~17.8V | 30.6~33.2V | 42.6~44.2V | ------ | |
Protection type:hiccup mode, auto-recovery after fault condition is removed | |||||
Over temperature | when temperature of transistor inner node is over150°C , start over temperature protection | ||||
Protection mode:cutoff output, auto-recovery after temperature become normal | |||||
environment | Workingtemp,humidity | -10°C ~+60°C, 20%~90%RH | |||
Storage temp.humidity | -20°C ~+85°C, 10%~95%RH non condensing | ||||
Withstand vibration | 10~500HZ, 2G 10min/1cycle, period for 60minutes, each axes | ||||
safety | Withstand voltage | I/P-O/P:1.5KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC | |||
Isolated resistance | I/P-O/P\I/P-FG\O/P-FG:100Mohms/500VDC | ||||
Fits tandard |
Safety standard | Fit UL1012, IP67 protect level | |||
EMC standard | Fit EN55022, CLASSA | ||||
Others | Dimension | 132*30*20mm(L*W*H) | |||
Weight/packing | 0.15kg/100pcs/16kg/0.027m3/0.94CUFT | ||||
Note |
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and25°C of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. |