Place of Origin: | China (Mainland) |
---|---|
Brand Name: | HD |
Model Number: | LPV-120W |
Output Power: | 101 - 200W |
Output Type: | Single |
Input Voltage: | 220V |
Output Voltage: | 12V/15V/24V/48V |
Output Frequency: | 47-63Hz |
Output Current: |
Quick Details
Specifications
Model | LPV-120-12 | LPV-120-24 | LPV-120-36 | LPV-120-48 | |
output | DC voltage | 12V | 24V | 36V | 48V |
Voltage tolerance | ±1% | ±1% | ±1% | ±1% | |
Rated current | 10A | 5A | 3.3A | 2.5A | |
Current range | 0~10A | 0~5A | 0~3.3A | 0~2.5A | |
Rated power | 120W | 120W | 118.8W | 120W | |
Ripple&noise | 100mvp-p | 150mvp-p | 150mvp-p | 180mvp-p | |
input | Voltage range | 180~264VAC, 255~373VDC | |||
Frequency | 47~63HZ | ||||
AC current | 1.2A/230VAC | ||||
Efficiency | 82% | 84% | 84% | 85% | |
Inrush current | Cold start current 40A/230VAC | ||||
Leakage current | <2.5mA/240VAC | ||||
protection | Over load | Rated output power 105%~135%start over load protection | |||
Protection type: hiccup mode,auto-recovery after fault condition is removed | |||||
Over voltage | 15.6~17.8V | 30.6~33.2V | 42.6~44.2V | 54.8~56.6V | |
Protection type: hiccup mode, auto-recovery after fault condition is removed | |||||
Over temperature | Shell temp≥85°C, start over temperature protection | ||||
Protection mode: cutoff output, auto-recovery after temperature become normal | |||||
environment | Working temp,humidity | -10°C~+60°C, 20%~90%RH | |||
Storage temp.humidity | -20°C~+85°C, 10%~95%RH non condensing | ||||
Withstand vibration | 10~500HZ, 2G 10min/1cycle, period for 60minutes, each axes | ||||
safety | Withstand voltage | I/P-O/P: 1.5KVAC I/P-FG: 1.5KVAC O/P-FG: 0.5KVAC | |||
Isolated resistance | I/P-O/P\I/P-FG\O/P-FG:100Mohms/500VDC | ||||
Fits tandard |
Safety standard | Fit UL1012, IP67 protect level | |||
EMC standard | Fit EN55022, CLASSA | ||||
Others | Dimension | 215*69*43mm(L*W*H) | |||
Weight/packing | 1.1kg/20pcs/23kg/0.03 m3/1.07CUFT | ||||
Note |
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and25°Cof ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. |