| Place of Origin: | China (Mainland) |
|---|---|
| Brand Name: | DVE |
| Model Number: | JZ2S(Y)75-2 |
| Structure: | Multistage Pump |
| Usage: | Oil |
| Power: | Electric |
| Standard or Nonstandard: | Standard |
| Fuel: | Vacuum Oil |
| Pressure: | |
| Application: | |
| Material: | Iron Cast |
Quick Details
Specifications
Roots Pump with Water(Liquid) Ring Pump Vacuum System
1. Able to be used to pump the gases with dust and vapor in the worse circumstances
2. Better vacuum, wider range of pumping gas, higher efficiency
3. Appropriate structure, high reliability&durabilit
4. Oil saving water saving, energy saving
5. High automation, simple to use, easy to maintenance
6. Able to be made as the vacuum system to pump corrosive gas as per request
Specification
Model : JZ2S(Y)75-2
Main Pump : ZJ75
Backing Pump : 2S(Y)K2
Ultimate Pressure(Pa) : Water Ring:300/Oil Ring:80
Displacement(L/s) : 75
Motor Power(kW) : 7.7
Suction(mm) : 100
Discharge(mm): 50
FEATURES
1.OEM supplier
2.Widely used
3.High reputation, good quality and pretty competitive price.
4.Flexibility
According to the need, DVE company can provide vacuum units with larger or smaller pumping capacity.
PACKING&DELIVERY
Packaging Detail: Depending on costumers,usually by plywood packaging
Delivery Detail: Depending on costumers' order quantity
APPLICATIONS:
It can be applied to the vacuum drying, vacuum degassing, vacuum concentration, vacuum evaporation, vacuum impregnation process in chemical industry, food, medicine, textile, papermaking, electrical and so on.
Main Specifications for Roots Pump with Double Stages Water(Liquid)Ring Pump Vacuum System
| Model | Main Pump | Backing Pump | Ultimate Pressure(Water Ring) | Ultimate Pressure(Oil Ring) | Displacement | Motor Power | Suction | Discharge |
| JZ2S(Y)75-2 | ZJ75 | 2S(Y)K2 | 300Pa | 80Pa | 75L/s | 7.7kW | 100mm | 50mm |
|
JZ2S(Y)75-1.5 |
ZJ75 |
2S(Y)K3 |
300Pa |
80Pa |
75L/s |
9.7kW |
100mm |
50mm |
|
JZ2S(Y)110-2 |
ZJ110 |
2S(Y)K3 |
300Pa |
80Pa |
110L/s |
9.7kW |
100mm |
50mm |
|
JZ2S(Y)150-1.5 |
ZJ150 |
2S(Y)K6 |
300Pa |
80Pa |
150L/s |
14kW |
100mm |
50mm |
|
JZ2S(Y)220-2 |
ZJ220 |
2S(Y)K6 |
300Pa |
80Pa |
220L/s |
15kW |
100mm |
50mm |
|
JZ2S(Y)300-1.5 |
ZJ300 |
2S(Y)K12 |
300Pa |
80Pa |
300L/s |
26kW |
150mm |
80mm |
|
JZ2S(Y)600-3 |
ZJ600 |
2S(Y)K12 |
300Pa |
80Pa |
600L/s |
29.5kW |
200mm |
80mm |
|
JZ2S(Y)600-1 |
ZJ600 |
2S(Y)25 |
300Pa |
80Pa |
600L/s |
62.5kW |
200mm |
100mm |
|
JZ2S(Y)1200-3 |
ZJ1200 |
2S(Y)K25 |
300Pa |
80Pa |
1200L/s |
66kW |
200mm |
100mm |
Main Specifications for Two Roots Pumps with Double Stages Water(Liquid)Ring Pump Vacuum System
| Model | Main Pump | Middle Pump | Backing Pump | Ultimate Pressure(Water Ring) | Ultimate Pressure(Oil Ring) | Displacement | Motor Power | Suction | Discharge |
| J2Z2S(Y)150-22 | ZJ150 |
ZJ75 |
2S(Y)K2 | 40Pa | 1Pa | 150L/s | 10.7kW | 100mm | 50mm |
|
J2Z2S(Y)150-21.5 |
ZJ150 |
ZJ75 |
2S(Y)K3 |
40Pa |
1Pa |
150L/s |
12.7kW |
100mm |
50mm |
|
J2Z2S(Y)300-42 |
ZJ300 |
ZJ75 |
2S(Y)K2 |
40Pa |
1Pa |
300L/s |
11.7kW |
150mm |
50mm |
|
J2Z2S(Y)300-41.5 |
ZJ300 |
ZJ75 |
2S(Y)K3 |
40Pa |
1Pa |
300L/s |
13.7kW |
150mm |
50mm |
|
J2Z2S(Y)300-32 |
ZJ300 |
ZJ110 |
2S(Y)K3 |
40Pa |
1Pa |
300L/s |
13.7kW |
150mm |
50mm |
|
J2Z2S(Y)300-21.5 |
ZJ300 |
ZJ150 |
2S(Y)K6 |
40Pa |
1Pa |
300L/s |
18kW |
150mm |
50mm |
|
J2Z2S(Y)600-32 |
ZJ600 |
ZJ220 |
2S(Y)K6 |
40Pa |
1Pa |
600L/s |
22.5kW |
200mm |
80mm |
|
J2Z2S(Y)600-21.5 |
ZJ600 |
ZJ300 |
2S(Y)12 |
40Pa |
1Pa |
600L/s |
33.5kW |
200mm |
80mm |
|
J2Z2S(Y)1200-41.5 |
ZJ1200 |
ZJ300 |
2S(Y)K12 |
40Pa |
1Pa |
1200L/s |
37kW |
250mm |
80mm |
|
J2Z2S(Y)1200-21.5 |
ZJ1200 |
ZJ600 |
2S(Y)K25 |
40Pa |
1Pa |
1200L/s |
73.5kW |
250mm | 100mm |
|
J2Z2S(Y)2500-41.5 |
ZJ2500 |
ZJ600 |
2S(Y)K25 |
40Pa |
1Pa |
2500L/s |
84.5kW |
300mm | 100mm |
Main Specifications for Three Roots Pumps with Double Stages Water(Liquid)Ring Pump Vacuum System
| Model | Main Pump | Middle Pump | Middle Pump | Backing Pump | Ultimate Pressure(Water Ring) | Ultimate Pressure(Oil Ring) | Displacement | Motor Power | Suction | Discharge |
| J3Z2S(Y)300-222 | ZJ300 |
ZJ150 |
ZJ75 | 2S(Y)K2 | 1Pa | 0.5Pa | 300L/s | 14.7kW | 150mm | 50mm |
|
J3Z2S(Y)300-221.5 |
ZJ300 |
ZJ150 |
ZJ75 |
2S(Y)K3 |
1Pa |
0.5Pa |
300L/s |
16.7kW |
150mm |
50mm |
|
J3Z2S(Y)600-232 |
ZJ600 |
ZJ300 |
ZJ110 |
2S(Y)K3 |
1Pa |
0.5Pa |
600L/s |
21.2kW |
200mm |
50mm |
|
J3Z2S(Y)600-221.5 |
ZJ600 |
ZJ300 |
ZJ150 |
2S(Y)K6 |
1Pa |
0.5Pa |
600L/s |
25.5kW |
200mm |
50mm |
|
J3Z2S(Y)1200-421.5 |
ZJ1200 |
ZJ300 |
ZJ150 |
2S(Y)K6 |
1Pa |
0.5Pa |
1200L/s |
29kW |
250mm |
50mm |
|
J3Z2S(Y)1200-232 |
ZJ1200 |
ZJ600 |
ZJ220 |
2S(Y)K6 |
1Pa |
0.5Pa |
1200L/s |
33.5kW |
250mm |
50mm |
|
J3Z2S(Y)1200-221.5 |
ZJ1200 |
ZJ600 |
ZJ300 |
2S(Y)K12 |
1Pa |
0.5Pa |
1200L/s |
44.5kW |
250mm |
80mm |
1, Inside the table above, the main pump could be" ZJ" pump, or" ZJP" pump with overflow valve; when" ZJP" is as the main pump," Z" should be changed to" ZP" , " S" represents Water Ring Vacuum Pump, while" Y" does Liquld Ring Vacuum Pump.
2, If Roots Vacuum Pump and Water(Liquid)Ring Pump are operated at 60Hz, the displacement should be increased to 1.2 times.