MODEL
|
S-500-12
|
S-500-13.5
|
S-500-15
|
S-500-24
|
S-500-27
|
S-500-48
|
OUTPUT
|
DC VOLTAGE
|
12V
|
13.5V
|
15V
|
24V
|
27V
|
48V
|
RATED CURRENT
|
40A
|
36A
|
32A
|
20A
|
18A
|
10A
|
CURRENT RANGE
|
0 ~ 40A
|
0 ~ 36A
|
0 ~ 32A
|
0 ~ 20A
|
0 ~ 18A
|
0 ~ 10A
|
RATED POWER
|
480W
|
486W
|
480W
|
480W
|
486W
|
480W
|
RIPPLE & NOISE (max.)
|
240mVp-p
|
240mVp-p
|
240mVp-p
|
240mVp-p
|
200mVp-p
|
300mVp-p
|
VOLTAGE ADJ. RANGE
|
10 ~ 13.2V
|
12 ~ 15V
|
13.5 ~ 18V
|
20 ~ 26.4V
|
26 ~ 32V
|
41 ~ 56V
|
VOLTAGE TOLERANCE
|
±1.0%
|
±1.0%
|
±1.0%
|
±1.0%
|
±1.0%
|
±1.0%
|
LINE REGULATION
|
±0.5%
|
±0.5%
|
±0.5%
|
±0.5%
|
±0.5%
|
±0.5%
|
LOAD REGULATION
|
±0.5%
|
±0.5%
|
±0.5%
|
±0.5%
|
±0.5%
|
±0.5%
|
SETUP, RISE, HOLD TIME
|
200ms, 50ms, 20ms at full load
|
INPUT
|
VOLTAGE RANGE
|
180 ~ 264VAC (110VAC input can be custom-made)
|
FREQUENCY RANGE
|
47 ~ 63Hz
|
EFFICIENCY (Typ.)
|
84%
|
84%
|
84%
|
86.0%
|
87.0%
|
88%
|
AC CURRENT
|
7A/115V 3.5A/230V
|
INRUSH CURRENT (max.)
|
18A/115V 36A/230V
|
LEAKAGE CURRENT
|
<3.5mA / 240VAC
|
PROTECTION
|
OVERLOAD
|
105 ~ 135% of rate load
|
Protection type : Fold back current limiting, recovers automatically after fault condition is removed
|
OVER VOLTAGE
|
13.8 ~ 16.2V
|
15.5 ~ 18.2V
|
18 ~ 21V
|
27.6 ~ 32.4V
|
31 ~ 36.5V
|
57.6 ~ 67.2V
|
Protection type : Hiccup mode, recovers automatically after fault condition is removed.
|
FAN CONTROL,O.T.P.
|
RTH1 or RTH250oC FAN ON,45oC FAN, 70oC output shut down
|
ENVIRONMENT
|
WORKING TEMP.
|
-10 ~ +60oC, 20 ~ 90% RH non-condensing
|
WORKING HUMIDITY
|
20 ~ 90% RH non-condensing
|
STORAGE TEMP., HUMIDITY
|
-20 ~ +85oC, 10 ~ 95% RH
|
TEMP. COEFFICIENT
|
±0.03%/oC (0 ~ 50oC)
|
VIBRATION
|
10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
|
SAFETY & EMC
|
SAFETY STANDARDS
|
Design refer to UL1950, TUV EN60950-1
|
WITHSTAND VOLTAGE
|
I/P-O/P:1.5KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
|
ISOLATION RESISTANCE
|
I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC
|
EMI CONDUCTION & RADIATION
|
Compliance to EN55022 (CISPR22) Class B
|
HARMONIC CURRENT
|
Compliance to EN61000-3-2,-3
|
EMS IMMUNITY
|
Compliance to EN61000-4-2,3,4,5,6,8,11;ENV50204,Light industry level,criteria A
|
OTHERS
|
MTBF
|
138.6K hrs min. MIL-HDBK-217F (25oC)
|
DIMENSION
|
240*125*65mm (L*W*H)
|
PACKING
|
1.35Kgs/pcs, 12pcs/17.7Kgs/0.0326CMB
|