| Place of Origin: | China (Mainland) |
|---|---|
| Brand Name: | HD |
| Model Number: | S-25W |
| Output Power: | 1 - 50W |
| Output Type: | Single |
| Input Voltage: | 220V |
| Output Voltage: | 5V/12V |
| Output Frequency: | 43-67Hz |
| Output Current: |
Quick Details
Specifications
| Model | HS-25-12 | HS-25-15 | HS-25-24 | ----- | |
| output | DC voltage | 12V | 15V | 24V | ----- |
| Voltage tolerance | ±1% | ±1% | ±1% | ----- | |
| Rated current | 2.1A | 1.7A | 1.1A | ----- | |
| Current range | 0~1.3A | 0~1.7A | 0~1.1A | ----- | |
| Rated power | 25.2W | 25.5W | 26.4W | ----- | |
| Ripple&noise | 100mvp-p | 120mvp-p | 150mvp-p | ----- | |
| DCvoltage ADJ.range | ±10% | ±10% | ±10% | ----- | |
| input | Voltage range | 90~264VAC, 235~373VDC | |||
| frequency | 47~63HZ | ||||
| AC current | 0.35A/230VAC | ||||
| efficiency | 78% | 78% | 80% | ----- | |
| Inrush current | Cold start current 30A/230VAC | ||||
| Leakage current | < 0.5mA/240VAC | ||||
| protection | overload | Rated output power110%~135% start over load protection | |||
| protection type :part layer type current limit , auto-recovery after fault condition is removed | |||||
| ----- | ----- | ||||
| ----- | |||||
| environment | Working temp,humidity | -10°C~+60°C, 20%~90%RH | |||
| Storage temp,humidity | -20°C~+85°C, 10%~95%RH non-condensing | ||||
| Withstand vibration | 10~500HZ, 2G 10min/1cycle, period for 60 minutes, each axes | ||||
| safety | Withstand voltage | I/P-O/P:1.5KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC | |||
| Isolation resistance | I/P-O/P,I/P-FG,O/P-FG:100Mohms/500VDC | ||||
| Fit standard | Safety standard | Compliance toUL1012 | |||
| EMC standard | Compliance toEN55022, CLASSA | ||||
| others | Dimension | 84*58*38mm(L*W*H) | |||
| Weight/packing | 0.15kg/80pcs/13kg/0.024m3/0.87CUFT | ||||
| note |
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and25°Cof ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. |
||||