Place of Origin: | China (Mainland) |
---|---|
Brand Name: | Hengtian |
Model Number: | HT-1000B |
Quick Details
Specifications
HT-1000B Supersonic Flowmeter Series are manufactured by modern technology, which is the first choice for the industries. The measurement principle of which are based on the difference of the flow speed. They're mainly used to measure the volume flow of the conductive fluid and slurry in a closed tube. With some characters such as good stability, small zero-drift error, high accuracy, widely measurement range (0.01~12m/s), strong anti-interference, etc. Functions: digital data transmission, reception, analysis, output and other new technologies.
Features:
High accuracy
linear feature is better than 0.5%, repeatability accuracy is better than 0.2%, measurement accuracy: volume flow is better than ±1%, heating is better than ±2%
Non-contact measurement
Put the sensor on the outside of the tube and then measure finished.
Large range of measuring
Caliber :DN15~DN6000mm
language menu
Chinese and English are available for reading.
Energy source
Ni-MH, rechargeable, large capacity, which could easily, ensured the flowmeter work more than 20 hours.
Printer inside
Print the data real-time, as well as the results according to customer comments.
Data recorder inside
This could load all the results into the computer and internet.
Application:
Chiller's cooling temperature, volume flow, cooling capacity measurement.
Hot water heating temperature, volume flow, heat measurement.
Heat exchanger temperature, flow, heat measurement.
Refrigerator output water temperature, volume, cooling measurement.
Boilers output temperature, volume, heating measurement.
Water cooling, alcohol, energy testing, house property and energy saving.
Parameters
Mainframe:
2*20 dot-matrix backlit LCD, temperature (-20~+60℃)
24 character TP
4*4+2 tipped keyboard
Data interface RS-485
Supersonic flowmeter sensor:
Standard TS-2 type caliber DN15~DN100mm, ambient temperature ≤ 110℃
Standard TM-1 type caliber DN50~DN1000mm, ambient temperature ≤ 110℃
Standard TL-1 type caliber DN300~DN6000mm, ambient temperature ≤ 110℃
High temperature mini HTS-1 type caliber DN300~DN6000mm, ambient Temperature ≤ 110℃
High temperature middle HTM-1 type caliber DN50~DN1000mm, ambient Temperature ≤ 110℃
Temperature sensor:
3 wire system, PT100 resistance, standard matching, deviation≤0.1 ℃
Medium (sound conduction): water, seawater, industrial sewage, acid-base liquid and all kinds of oils.
Flow speed: 0~±30m/s
Accuracy:
Volume flow- better than ±1%, heating- better than ±2%
Energy source: NI-MH battery, work continuously more than 20 hours. Or AC220V
Power: 1.5W
Adopt intelligent charging style, direct access AC220V. Automatically power off and then green light works when recharge finished.
N.W.: 2.5Kg (mainframe)
Remark: Equipped with highly protective box and could work under extreme fields.
Features:
High accuracy
linear feature is better than 0.5%, repeatability accuracy is better than 0.2%, measurement accuracy: volume flow is better than ±1%, heating is better than ±2%
Non-contact measurement
Put the sensor on the outside of the tube and then measure finished.
Large range of measuring
Caliber :DN15~DN6000mm
language menu
Chinese and English are available for reading.
Energy source
Ni-MH, rechargeable, large capacity, which could easily, ensured the flowmeter work more than 20 hours.
Printer inside
Print the data real-time, as well as the results according to customer comments.
Data recorder inside
This could load all the results into the computer and internet.
Application:
Chiller's cooling temperature, volume flow, cooling capacity measurement.
Hot water heating temperature, volume flow, heat measurement.
Heat exchanger temperature, flow, heat measurement.
Refrigerator output water temperature, volume, cooling measurement.
Boilers output temperature, volume, heating measurement.
Water cooling, alcohol, energy testing, house property and energy saving.
Parameters
Mainframe:
2*20 dot-matrix backlit LCD, temperature (-20~+60℃)
24 character TP
4*4+2 tipped keyboard
Data interface RS-485
Supersonic flowmeter sensor:
Standard TS-2 type caliber DN15~DN100mm, ambient temperature ≤ 110℃
Standard TM-1 type caliber DN50~DN1000mm, ambient temperature ≤ 110℃
Standard TL-1 type caliber DN300~DN6000mm, ambient temperature ≤ 110℃
High temperature mini HTS-1 type caliber DN300~DN6000mm, ambient Temperature ≤ 110℃
High temperature middle HTM-1 type caliber DN50~DN1000mm, ambient Temperature ≤ 110℃
Temperature sensor:
3 wire system, PT100 resistance, standard matching, deviation≤0.1 ℃
Medium (sound conduction): water, seawater, industrial sewage, acid-base liquid and all kinds of oils.
Flow speed: 0~±30m/s
Accuracy:
Volume flow- better than ±1%, heating- better than ±2%
Energy source: NI-MH battery, work continuously more than 20 hours. Or AC220V
Power: 1.5W
Adopt intelligent charging style, direct access AC220V. Automatically power off and then green light works when recharge finished.
N.W.: 2.5Kg (mainframe)
Remark: Equipped with highly protective box and could work under extreme fields.