| Place of Origin: | China (Mainland) |
|---|---|
| Brand Name: | Worldsure |
| Model Number: | XGN2-12 |
| Max. Current: | 3150 A |
| Max. Voltage: | 10 kV |
| Voltage: | 3/6/10 kv |
| Temperature: | -25 ~ +40 |
| Humidity: | < 95% |
| Altitude: | < 1000m |
| Protection class: | IP 2X |
| Standard: | IEC298 |
| Frequency: | 50/60Hz |
| Size: | 1100*1200*2650 mm |
Quick Details
Specifications
XGN2-12 Fixed Type Metal-Clad Switchgear
Type: XGN2-12
Application
Our XGN2-12 Fixed Type Metal-Clad Switchgears are suitable for 3.6, 7.2, 12KV 3-phase AC 50/60Hz power system. Used for power receiving and distribution.
General
XGN2-12 Fixed Type Metal-Clad Switchgear is a box-type, fixed and enclosed equipment , suitable for occasions of frequent operation. The elemental framework is made of welded angle irons. The main switch of this cabinet adopts vacuum contactor or ZN28A-10(12) series vacuum circuit breakers and CT series spring maneuvering mechanism. Isolating switch adopts GN30-10 super current isolating switch series
Ambient conditions
- Ambient temperature: upper limit +40; lower limit: -25
- Altitude no more than 1000m
- Relative humidity: daily average humidity no more than 95%, and monthly average no more than 90%
- Steam pressure: daily average pressure no greater than 2.2×103MPa, monthly average no greater than 90%
- Seismic intensity no greater than 8 degree
- No fire, explosive danger, grave filth, chemical corrosion and drastic vibration on the site.
Advantages
- This switchgear is case metal-enclosed structure. In accordance with the national standard GB3906 and international standardIEC298, protection degreeIP2X. The metal-enclosed structure effectively prevents short-circuit failure by intruders .
- When air insulation distance between polar to polar or polar to ground ≤125mm, porcelain support insulators (≥8000N) is applied. All these ensure higher insulation intensity and stability.
- Breakers, both upper and lower insulation switches, grounding switches and interlock mechanisms between doors all takes force mechanical lock mode to meet the requirement of "five- prevention".
Major technical parameters of Switchgear
No. | Name | Unit | Data | |||
1 | Rated Voltage | KV | 3,6,10 | |||
2 | Rated Current | A | 630,1000,1250,1600, 2000,2500,3150 | |||
3 | Rated Frequency | Hz | 50 | |||
4 | Rated short-circuit current(valid value) | kA | 20, 25 | 31.5 | 40 | |
5 | Rated ripe stable current (peak value) | kA | 20, 25 | 31.5 | 40 | |
6 | Rated dynamic stable current(peak value) | kA | 40 | 80 | 100 | |
7 | Rated power frequency tolerant voltage | Inter-polar /polar to ground | kV | 42 | ||
Inter-fracture | kV | 48 | ||||
8 | Rated lightening shock tolerance voltage | Inter-polar /polar to ground | kV | 75 | ||
Inter-fracture | kV | 85 | ||||
9 | Rated thermal time | s | 4 | |||
10 | Protection degree |
| 1P2X | |||
11 | Outline dimensions | mm | 1100*1200*2650 (see the note) | |||