| Technical Specification |
| ITEM | UNIT | SPECIFICATION | REMARK |
| INPUT |
| 1 | Rating Input Voltage | V ac | 100-249Vac 50/60Hz |
|
| 2 | Input Voltage Range | V ac | 90-264Vac |
|
| 3 | Rating Input Current | A | 1.1Arms | INPUT:220V OUTPUT:Full load |
| 4 | Max. input power | W | 80 |
|
| OUTPUT |
| 5 | Rating Output Voltage | V dc | 29.3Vdc |
|
| 6 | Output Voltage Range | V de | 21-29.4Vdc |
|
| 7 | Suit with Battery Type |
| 25.9V(7Serial) 4-12Ah Li-Ion |
|
| 8 | Charging Current | A | 2.0±0.15@28V |
|
| 9 | Charging Voltage | V | 29±0.2V |
|
| 10 | Cut-off Current | A | <0.2A |
|
| 11 | Typical Charging time | hour | ~~ |
|
| 12 | Max. output power | W | 60W |
|
| 13 | Hold-on time | ms | NC | Input: 220Vac Output:Full load |
| 14 | Ripple Current | mA | 100 | Input: 220Vac Output:Full load |
| 15 | Charge Finish condition |
| V>29.3V + I<0.2A |
|
| 16 | LED color |
| Red: charging Green:finish/idle |
|
| 17 | Output protect | ~ | OCP&OVP |
|
| 18 | Efficiency | % | 80% | At max.load |
| Environment |
| 19 | Operate temperation | Celsius degree | -10~+40 | Full load & natural convection |
| 20 | Operate humidity | %RH | <+90 | Relative humidity, non-condensing |
| 21 | Storage temperature | Celsius degree | -40~ +7-0 |
|
| 22 | Storage humidity | %RH | 0~ +95 | Relative humidity, non-condensing |
| 23 | Cooling | - | Natural convection |
|
| 24 | Temperature factor | % | -- |
|
| 25 | Vibration resistance |
| 5MM/50HZ/600S | Non-operating condition |
| 26 | Impact resistance |
| 1 meter drop test>=3 times | Non-operating condition |
| Mechanical |
| 27 | Weight | g | 550 |
|
| 28 | Size | mm | 129x91x68 | Casing only |
| 29 | Connectors | - | Defined when order |
|
| Safety |
| 30 | Max.temperature size | Celsius degree | <40 on casing | At any line and Max.load |
| 31 | Safety standards | - | EN60335-2-29 |
|
| 32 | EMC standard | - | EN55014 |
|
| 33 | MTBF | hrs | 30000 |
|
| 34 | Limited power source | VA | - |
|
| 35 | ESD | kV | 8 |
|
| 36 | Hi-Pot Insulation | V | i/p to o/p:3000(1min) | For final unit, cut-off current=10mA |