Product Main

Quick Details

Place of Origin: China (Mainland)
Brand Name: caledonian
Model Number:
Insulation Material: PVC
Type: Medium Voltage
Application: Power Station
Conductor Material:
Jacket: PVC

Specifications

PVC Insulated, PVC Sheathed and Armoured Power Cable

Voltage Rating
Voltage:0.6/1.0kV (Um=1kV)


Conductors :

Plain annealed stranded copper conductor

Insulation :

Flame retardant PVC compound

Filler (where applicable) :

PVC or Polypropylene yarn

Armoring:

Aluminium wire armored or steel wire armored

Binder Tape (where applicable) :

Polyester (mylar) tape

Sheath :

Flame retardant PVC compound


Core identification

Insulation

1-Core :

Red, Yellow, Blue, Black, Green/Yellow or other colors as per customer's request

2-Core :

Red and Black

 

3-Core :

Red, Yellow and Blue

 

4-Core :

Red, Yellow, Blue and Black

 

Sheath

Black, Grey or White

 


Test Standards

Design Standard

Material Compliance Standard

Flame Retardancy Standard

BS 6360

BS 7655

BS 4066 PART 1

IEC 60227-3

IEC 60811

IEC 60332-1

IEC 60228

.

BS 4066 PART 3

IEC 60502-1

.

IEC 60332-3


600/1000V Single Core PVC Insulated PVC Sheathed Armoured Cable to BS 6346

600/1000V Two Core PVC Insulated PVC Sheathed Armoured Cable to BS 6346

600/1000V Three Core PVC Insulated PVC Sheathed Armoured Cable to BS 6346

600/1000V Four Core PVC Insulated PVC Sheathed Armoured Cable to BS 6346

600/1000V Multicore PVC Insulated PVC Sheathed Armoured Cable to BS 6346

1900/3300V Single Core PVC Insulated PVC Sheathed Armoure d Cable to BS 6346

1900/3300V Three Core PVC Insulated PVC Sheathed Armoure d Cable to BS 6346

 

Power Cables

600/1000V SINGLE-CORE PVC INSULATED, PVC SHEATHED, ARMOURED CABLE TO BS 6346

Construction
Conductor :
Plain annealed copper
Insulation : Flame retardant PVC compound
Filler: PVC or Polypropylene yarn
Binder Tape: Polyester (mylar) tape
Bedding: Flame retardant PVC compound
Armouring: Aluminium wire armored
Sheath: Flame retardant PVC compound

Size of Conductor

Nominal Thickness of Insulation

ALUMINIUM WIRE ARMOURED (AWA) CABLE

Nominal Thickness of Bedding

Nominal Dia. of Armour Wire

Nominal Thickness of Sheath

Approx. Overall Diameter

Approx. Weight

mm2

mm

mm

mm

mm

mm

kg/km

50

1.4

0.8

1.25

1.5

19.1

795

70

1.4

0.8

1.25

1.6

21.1

1045

95

1.6

0.8

1.25

1.6

23.4

1360

120

1.6

1.0

1.6

1.7

26.3

1720

150

1.8

1.0

1.6

1.7

28.3

2050

185

2.0

1.0

1.6

1.8

30.8

2500

240

2.2

1.0

1.6

1.9

34.1

3160

300

2.4

1.0

1.6

1.9

37.0

3850

400

2.6

1.2

2.0

2.1

42.0

4960

500

2.8

1.2

2.0

2.1

45.6

6060

630

2.8

1.2

2.0

2.2

49.7

7545

800

2.8

1.4

2.5

2.4

55.8

9630

1000

3.0

1.4

2.5

2.5

61.0

11855