1.GD-5208 Rapid Low Temperature Closed Cup Flash Point Tester 
2.Determination of flashpoint 
3.ISO3679 Rapid equilibrium method 

GD-5208 Rapid Low Temperature Closed Cup Flash Point Tester

 

 

 

 

Summary:

 

GD-5208 Rapid Low Temperature Closed Cup Flash Point Tester is designed and made as per the National Standard of People's Republic of China GB/T5208 " Test Methods for Flash Point (Rapid Equilibrium Closed Cup Method)" .

GD-5208 Rapid Low Temperature Closed Cup Flash Point Tester can be used in the field of petroleum, chemistry, paints, railway, aviation, power plant, inspection, military, and scientific research to determine flash point of petroleum products rapidly.

 

GD-5208 Closed Cup Flash Point Tester is suitable to make closed cup flash point determination for paints, adhesives, solvents, petroleum, and relative petroleum products, the flash points of which are in the range of 30°C~50°C. It can also meet the requirements ofASTM D3934, ISO 1523 and ISO 3679.

 

 

Main technical characteristics:

 

1. It is designed as per GB/T5208 (Test Methods for Flash Point (Rapid Equilibrium Closed Cup Method)" . It can determine closed cup flash point at a low temperature rapidly.
2. It adopts semiconductor refrigeration device and cooling water refrigeration device. It is small, convenient and with rapid refrigeration speed.
3. It needs fewer samples. The sample for each test is only 2 ml (For solid or semisolid sample, it is 4 ml);
4. The test can be automatically completed excepting flame ignition. The test data can be automatically printed.



Main technical specification and parameters:

 
Power Supply       AC 220V±10%, 50 Hz
Flash point measurement range-30~50°C
Measurement accuracyRepeatability: less than 2°C
Reproducibility: less than 2°C
Temperature controlling accuracy±0.5°C
Igniteran electron igniter
Refrigeration typeIt uses semiconductor for refrigeration (It connects to outer cooling water);
Power supplyAC 220V±10%, 50 Hz
Total power consumptionnot more than 300 W
Ambient temperature5°C~30°C
Relative humidity30~80%

 

 
Packaging List of GD-5208 Laboratory Rapid Highly Flammable Flash Point Tester  
 

No.

Production Name

Unit

Quantity

1

GD—5208 Rapid Low Temperature Closed Cup Flash Point Tester

Set

1

2

Fuse Φ5×20  10A

PC

2

3

Power wire(250V 10A)

Root

1

4

Printing paper

Roll

2

5

Ignition gun

PC

1

6

Rubber hose(Inner Dia 8,for water flow)

m

3

7

5ml sampler(including pin head)

PC

1

 

 

More Closed Cup Flash Point Apparatus:

 

GD-261A Automatic Pensky-Martens Closed Cup Flash Point Tester
GD-261D Fully-automatic Pensky-Martens Closed Cup Flash Point Tester
GD-261-1 Pensky-Martens Closed Cup Flash Point Tester
GD-261 Pensky-Martens Closed Cup Flash Point Tester
GD-5208 Rapid Closed Cup Flash Point Tester
GD-5208A Rapid High-temperature Closed Cup Flash Point Tester
GD-5208D Rapid Low-temperature Closed Cup Flash Point Tester

 

 

 