| Place of Origin: | China (Mainland) |
|---|---|
| Brand Name: | OEM |
| Model Number: | AD |
| Output Type: | DC |
| Connection: | Plug In |
Quick Details
Specifications
1. General
This specification defines the performance characteristic of an AC/DC switching adapter. The adapter must comply with all the requirements of the specifications and drawing herein. The requirements can be subject to revision in the future discussion.
2. Electrical Performance and Tests
2.1. Input
Voltage: AC100V - 240V
Frequency: 50/60Hz
Current: Maximum 260mA @ 100VAC and maximum 150mA @ 240VAC
Inrush Current: <20A@240VAC 50Hz (COOL)
Standby power: <0.3W
Rating Input load power: 16W max
Starting Time <1S@240VAC Io=100%
2.2. Output
Voltage: 12.0V±5%
Current: 1A
Ripple & Noise: Maximum200mVP-P @ 100%
Note: 20MHz bandwidth ripple & noise is measured by using 0.1uF C.C. & 47uF E.C. bypassed at the output connector.
2.3. Hi-pot Test
Applying 3000VAC for 1 minute, leakage current must be less than 5mA.
2.4. Insulation Resistance
Minimum100Mohms @ DC500V
2.5. Short Circuit Protection
No damage to this power supply when output shorted to ground. When the short-circuited is removed, the adapter shall promptly recover its normal operation.
3. Mechanical Tests and Requirements
3.1. Drop Test
Drop height:1.0mabove50mmhardwood.
Method: Total 4 times. Drop one time for each of the 4 case surfaces.
Expected result: After drop test, the unit should still operate properly. Small nick or slight deformation may be accepted.
3.2. Cord Bending Test
Bending angle: +60 degree
Bending rate: 20 times / minute
Loading:200g
Expected result: After 200 times of bending, the numbers of broken copper wire should be less than 50% of total numbers.
4. Environmental Conditions
4.1. Operating Temperature
0℃~ +40℃
4.2. Storage Temperature
-20℃~ +60℃
4.3. Humidity
90%RH Non-condensing
5. Safety Standard
EN60950
6. Electromagnetic Compatibility
EN 50081-1 EN50082-1 EN61000-3-3
7.1. Dimension
73mm X 29mm X 62.3mm