Place of Origin: | China (Mainland) |
---|---|
Brand Name: | Anthone |
Model Number: | LU-C1000 |
Price: |
Quick Details
Specifications
Our Paperless Recorders support universal inputs, may be T.C, RTD,
standard voltage, standard current signals etc., the recorder may
provide the sensors power supply out. Through Direct connecting to the
miniature printer, may print the real-time historical data and the curve
that the user assign. Through the RS232 communication connector to
connect with the computer & the palm computer (PAD), may straightly
read the history data, and then send to the computer. Through data
management software, may analyze, archive, print the read data. Through
RS485 communication connector, can real-time monitor the system with the
configuration king, MCGS and so on specialized configuration. And
through the modern USB communication connector, may Store the data to
U-disk directly, the recorded time is longer.
The recorder has much display function, the real-time trend curve display, big digital display, historical curve recalls, ultra limits alarm, alarm status display, with the function of intellectualized historical tendency automatically return to display, convenient for looking over the alarm point, simultaneously may redisplay the data, convenient & quick for directly inquiring the year, month, date, hour, minute and second.
1. Brief Introduction
LU-C1000 series recorders may be 1 to 3 channels programmable PID control and the program control curve may reach 100 segments.
2. Technical parameter
◆ Outline dimension: 160*80cm
◆ Input accuracy: ± (0.2%F.S+1) digit
◆ Input type:
standard voltage 0-5V, 1-5V
standard current 0-10mA, 4-20mA
T.C: K, S, B, T, E, J, Wre325, N
RTD: Pt100, Cu50, Cu100
specially input: R, WRe526, the mV signal, other
(indicated when ordering)
◆ Output type:
Switch output: Relay (resistance 250VAC/0.8A or 250VAC/3A)
Linear current output: 0-10mA, 4-20mA, 0-20mA (software sets freely)
Linear voltage output: 0-5V, 1-5V, 0-10V (indicated when ordering)
Silicon-controlled zero-crossing trigger
SSR trigger (12V/50mA)
Sensor power supply: DC12V/50mA
DC24V/50mA
DC5V/50mA
transform output: 4-20mA (load <650Ω), 1-5V
0-10mA (load <1000Ω), 0-5V
communication connection: RS232 or RS485
storage medium: U disk/512M, U disk/1G, U disk/2G,
◆ 5 to 100 segments of control curves
◆ Power off protection time: the data can be stored forever when the power is cut off because it adopts FLASH MEMORY,
it can run accurately when power off because hard clocks is equipped.
◆ Power: Switch power supply 85VAC-264VAC, 50Hz±1Hz, power consumption is 12W;
◆ Ambient temperature: 0-45 ℃
◆ Ambient humidity: 0-85%RH
The recorder has much display function, the real-time trend curve display, big digital display, historical curve recalls, ultra limits alarm, alarm status display, with the function of intellectualized historical tendency automatically return to display, convenient for looking over the alarm point, simultaneously may redisplay the data, convenient & quick for directly inquiring the year, month, date, hour, minute and second.
1. Brief Introduction
LU-C1000 series recorders may be 1 to 3 channels programmable PID control and the program control curve may reach 100 segments.
2. Technical parameter
◆ Outline dimension: 160*80cm
◆ Input accuracy: ± (0.2%F.S+1) digit
◆ Input type:
standard voltage 0-5V, 1-5V
standard current 0-10mA, 4-20mA
T.C: K, S, B, T, E, J, Wre325, N
RTD: Pt100, Cu50, Cu100
specially input: R, WRe526, the mV signal, other
(indicated when ordering)
◆ Output type:
Switch output: Relay (resistance 250VAC/0.8A or 250VAC/3A)
Linear current output: 0-10mA, 4-20mA, 0-20mA (software sets freely)
Linear voltage output: 0-5V, 1-5V, 0-10V (indicated when ordering)
Silicon-controlled zero-crossing trigger
SSR trigger (12V/50mA)
Sensor power supply: DC12V/50mA
DC24V/50mA
DC5V/50mA
transform output: 4-20mA (load <650Ω), 1-5V
0-10mA (load <1000Ω), 0-5V
communication connection: RS232 or RS485
storage medium: U disk/512M, U disk/1G, U disk/2G,
◆ 5 to 100 segments of control curves
◆ Power off protection time: the data can be stored forever when the power is cut off because it adopts FLASH MEMORY,
it can run accurately when power off because hard clocks is equipped.
◆ Power: Switch power supply 85VAC-264VAC, 50Hz±1Hz, power consumption is 12W;
◆ Ambient temperature: 0-45 ℃
◆ Ambient humidity: 0-85%RH