Place of Origin: | China (Mainland) |
---|---|
Brand Name: | MINGRUI |
Model Number: | MRD-BJ |
Quick Details
Specifications
Neutral grounding resistor
A. areas of usage
1. Common reasons for using neutral grounding resistor
a. reducing single phase fault currents which occur in M.V. electrical networks to prevent damages on transformers and generators
b. reducing temporary over voltage occurred by braking instantaneous fault current, providing long-life for switchgear
c. reducing step voltage to a harmless level for staff
Neutral grounding resistors are used for resistance grounding of industrial power system. They are generally connected between ground and neutral of transfomers, generators and grounding transformers. Neutral grounding resistors are used in order to limit maximum fault current to a value which will not damage the equipment in the power system, yet allow sufficient flow of fault current to operate protective relays to clear the fault. Although it is possible to limit fault currents with high resistance neutral grounding resistors, phase to ground short circuit currents can be extremely reduced. As a result of this fact, protection devices may not sense the fault. Therefore, it is the most common application to limit single phase fault currents with low resistance neutral grounding resistors.
B. Features
Stainless-steel resistor elements
Current transformer included (EN60044-1)
Bolted resistor element connections instead of welded connections in order to be able to assemble spare parts on site immediately.
MINGRUI resistors are designed to absorb a large amount of energy without exceeding temperature limitations defined in IEEE32. Neutral Grounding Resistors MINGRUI manufacture can be used for indoor and outdoor and the neutral point is connected with a porcelain bushing or with a high voltage cable from the bottom, top or side. The most common protection degree preferred for Neutral grounding resistors is IP23 as it allows the resistor elements to cool easier and they can be used both at sea shores and deserts because the resistor elements are completely stainless steel and does not affected by extreme conditions. Neutral grounding resistors are shipped with maintenance and installation guide, in which, recommended relay settings for each Neutral grounding resistor are stated as well. MINGRUI provides complete technical assistance in order to meet your specifications or site conditions.
B.a Technical Specifications
Operation voltage: up to 110kV line to line systems
Rated current (A): up to 2000
Ambient temperature :<55
Resistance alloy: stainless steel
Protection degree: IP23(outdoor) and others
Standards: IEEE32, IEC60137, IEC60298, IEC60273, IEC60071, IEC60060
C. b
2mm hot dip galvanized steel enclosure
Stainless steel or aluminum enclosures are available on demand
Typically, RAL7032 paint for enclosure (other colors are available on demand)
Solid top cover sloped to prevent water accumulation
Custom made lifting eye bolts for securing lifting
Front cover for easy access to connection and inspection doors available on demand
Corrosion resistant stainless steel nameplate
B.c Options
Elevated support standard are provided for ground clearance and safety
Specially designed units for hazardous and extreme locations
Stainless steel or aluminum enclosures on demand
Installation of voltage transformers
Installation of protection relays
Porcelain entrance bushings can be mounted on top or on the side of Neutral grounding resistor
Grounding transformer installation
Motorized or manual single pole disconnector switches, load bank switches, surge arresters and heaters in the Neutral Grounding Resistors
C. TESTS
C.a. Routine tests
Measurement of insulation resistance between enclosure and resistor
Withstand test of dielectric strength at network frequency for one minute
Measurement of total DC resistance
Insulation test or resistor blocks
Galvanization thickness test
Paint thickness test
C.b Type Test (on demand)
Temperature rise test
Protection degree test
Impulse voltage test
Measurement of AC resistance
Seismic test
D. Selection details
System voltage
Line to neutral voltage
Desired current rating
Desired resistance level
Maximum time ON (seconds)
Bushing entry or cable entry
Current transformer ratio (if applicable)
Disconnector switch (if applicable)
Special options (if applicable)