Product Main

Quick Details

Place of Origin: China (Mainland)
Brand Name: NE Sensor
Model Number: 4NE/7NE
Usage: Gas Sensor
Theory: Optical Sensor
Output: Analog Sensor

Specifications

 

Intelligent Gas Sensor

Product  introduction

      4NE/7NE series of Intelligent Gas Sensor Is designed for gas detector manufacturers to launch new intelligent sensor, mainly to solve the problem there are many different kinds of gas detection, calibration of sensor are incompatible each type, production complex, core component replacement limit and so on. Use the intelligent gas sensor of our company need to develop a product, you can quickly response to customer demand for different types of gas detection, and simplify the production process, the need to calibration, reduce the cost of enterprise research and development costs, production, product quality also immediately ascend to the international first-class level.

The sensor is easy to operate, measurement accuracy, reliable operation, and suitable for industrial field or laboratory measurements of different requirements. Sensor has a voltage and a serial port output characteristics at the same time, convenient debugging and use.

Applications

Intelligent gas gas sensor is mainly used in the field of poisonous and harmful gas detection, air pollution monitoring, industrial safety testing, indoor environment testing, various needs gas testing environment, 4NE mainly used for intermittent detection products, such as: gas detector, gas leak detection instrument, experimental analysis and detection field all need only for short periods of time, NE mainly used in on-line continuous inspection field, such as: gas analyzer, gas alarm, so all need 24-hour monitoring of the environment for a long time.

Features of ND Sensor

The Ann circuit design, can be with electric plug pull operation;

Professional, original imported, compatible with infrared, electrochemistry, catalysis, semiconductor and other sensors;

With temperature compensation, the factory precision calibration, when using, no need to calibration;

Voltage/Current and the serial port output characteristics at the same time, convenient debugging and use;

The most simplified peripheral circuit, the production is simple and convenient operation.

Specifications

Detection Gas

Gas toxic, flammable gas, volatile organic compounds

Measuring Range

0-10000 ppm (To detect gas)

Accuracy

±2% FS

Response Time

0 ~ 80% < 30sec

Testing Principle

Catalysis, electrochemistry, infrared

Warm-Up Time @25℃

< 30sec

Operating Condition

-2070, 0 ~ 95%RH (Non Condensing), 86kPa106kPa

Output 

Analog : 4-20mA(only7NE), 0.4-2.0VDC(convention), 0-1.6VDC, 0-4VDC, 0-5VDC optional

UART : 9600 bps (DATE BITS: 8; TSTP: 1; Check bit: No; )

Power Input

working voltage : DC5V±1% Input

(4-20mA output should DC24V)

Consumption Current

50mA

Installation

7 feet pull plug type

Measurement unit

PPM, %LEL, %VOL(To detect gas)

Repeatability

±1%FS

Zero drift for a long time

1%FS/year

Storage Temperature

-4070

Shell material

aluminum alloy

output interface

7PIN

working life

More than 2 years

Guarantee period

1year

Size

4NE Φ21.5*31mm(Except the pin)

7NE Φ33.5*31mm(Except the pin)

Size Specificationsp

Outer size Diagram                                              Installation Sketch

 

7NE Size

Outer size Diagram                                              Installation Sketch

4NE Size

Pin definition

pin

Title

explain

1

location

Stitching positioning

2

VCC

+5V/24V Input Pow

3

GND

earth wire

4

VOUT

voltage output

5

RXD

UART receive

6

TXD

UART send

7

RDE

UART output control