Product Main

Quick Details

Place of Origin: China (Mainland)
Brand Name: ees cable
Model Number:
Type: Insulated
Application: Underground
Conductor Material: Aluminum
Conductor Type: Stranded
Insulation Material: PVC

Specifications

Product Description

Specifications 
High quality, 
Fast delivery 
And competitive price 
Specifications 
1. Low voltage 
2. AAC/AAAC/ACSR conductor 
3. Best price and reliable quality 
4. ISO 9001& ISO14001 
We can produce XLPE(PE) insulated ABC cable (service drop) as per GB, IEC, ASTM Standard with high quality&competitive price. 

Brief description: 
Aerial Bundled Cable(ABC) has an aluminium conductor with a PVC OR XLPE sheath. ABC usually has 3 cores plus neutral, the neutral can either be bare or insulated and the cable can have a street light of 25mm2 . ABC is available in 600/1000v, 635/11kV or 12, 7/22kV. We stock 1 core, 2 core and 3 core ABC cable. 

XLPE(PE) insulated ABC cable (service drop) 
1. Applications: 
Primarily used for overhead service applications such as street lighting. Outdoor lighting, and temporary service for construction. To be used at voltages of 600V phase-to-phase or less and at conductor temperatures not to exceed 75° C for polyethylene insulated conductors or 90° C for crossliked polyethylene(XLPE) insulated conductors. 
2. Construction: 
Concentric strand or compressed 1350-H19 conductor, poly- ethylene or cross linked polyethylene insulation, concentric strand AAC, ACSR or 6201 alloy neutral messenger. 
3. Type of XLPE(PE) insulatedabc cable (service drop) 
XLPE(PE) insulatedabc cable (service drop)covers mainly three types: 
Duplex Service Drop 
Triplex Service Drop 
Quadruplex Service Drop 

The cable can be produced whose construction is phase conductor with neutral bare conductor or phase conductor with insulated neutral conductor, etc. And we can still produce the cables according to the request of customers. 

4. Detaild Introduction of XLPE(PE) insulatedabc cable (service drop) 
4.1 Duplex Service Drop 
Applications 
To supply 120 volt aerial service for temporary service at construction sites, outdoor or street lighting. For service at 600 volts or lower at a conductor temperature of 75 maximum. 

4.2 Triplex Service Drop 
Applications 
To supply power from the ulility`s lines to the consumer`s weatherhead. For service at 600 volts or less(phase to phase ) at a conductor temperature of 75 maximum for PE insulation or 90 maximum for XLPE insulation. 

4.3 Quadruplex Service Drop 
Applications 
Used to supply 3 phase power, usually from a pole-mounted transformer to the use`s servic head where connection to the service entance cable is made. To be used at voltages of 600 volts or less phase to phase and at conductor temperature not to exceed 75 for PE insulated conductors or 90 for XLPE insulated conductors. 

5. Standards 
1. B-230 Aluminum Wire, 1350-H19 for Electrical Purposes. 
2. B-231 Aluminum Conductors, Concentric-Lay-Stranded. 
3. B-232 Aluminum Conductors, Concentric-Lay-Stranded, Coated Steel Reinforced (ACSR). 
4. B-399 Concentric-Lay_Stranded 6201-T81 Aluminum Alloy Conductors. 
5. B498 Zinc-Coated Steel Core Wire for Aluminum Conductors, Steel Reinforced (ACSR). 
6. Duplex Service Drop cable meets or exceeds all applicable requirements of ANSI/ICEA S-76-474

Code*Word Phase conductor Bare Neutral Message Nominal lay Length Weight Per
1000 ft.(lbs.)
Allo wable Amp acitles
Size
(A WG)
Stranding Insul
Thick(Mils)
Size
(AWG)
Stranding Rated
Strength
(lbs.)
inches XLP POLY XLP POLY
AAC Neutral-messenger
Pekingese 6 1 45 6 7 563 10.36 61 61 85 70
Collie 6 7 45 6 7 563 10.36 64 64 85 70
Dachshund 4 1 45 4 7 881 10.36 92 92 115 90
Spaniel 4 7 45 4 7 881 10.36 96 96 115 90
Doberman 2 7 45 2 7 1350 14.88 147 147 150 120
Malemute 1/0 9 60 1/0 7 1990 14.88 234 234 205 160
 
Triplex low voltage twisted ABC Cable
Code*Word Phase conductor Bare Neutral Message Nominal lay Length Weight Per
1000 ft.(lbs.)
Allo wable Amp acitles
Size
(A WG)
Stranding Insul
Thick(Mils)
Size
(AWG)
Stranding Rated
Strength
(lbs.)
inches XLP POLY XLP POLY
AAC Neutral-messenger
Pateela 6 7 45 6 7 563 14.88 103 103 85 70
Oyster 4 7 45 4 7 881 14.88 154 154 115 90
Clam 2 7 45 2 7 1350 20.58 233 233 150 120
Murex 1/0 7 60 1/0 7 1990 20.58 374 374 205 160
Purpura 1/0 9 60 1/0 7 1990 20.58 368 368 205 160
Nassa 2/0 7 60 2/0 7 2510 25.42 462 462 235 185
Melita 3/0 17 60 3/0 19 3310 29.97 562 562 275 215
Portunus 4/0 18 60 4/0 19 4020 29.97 696 696 315 245
Nannynose 336.4 19 60 336.4 19 6146 38.79 1118 1118 420 325
*Code words for XLP insulated products are formed by adding "/XLP" to the conventional code words above (e.g.-Chihuahua/XLP)
+Conductor temperature of 90 for XLP,75 for Poly;ambient temperature of 40;emissivity 0.2;2ft./sec.Wind in sun.
 
Quadruplex   low voltage twisted ABC Cable
Code*Word Phase conductor Bare Neutral Message Nominal lay Length Weight Per
1000 ft.(lbs.)
Allo wable Amp acitles
Size
(A WG)
Stranding Insul
Thick(Mils)
Size
(AWG)
Stranding Rated
Strength
(lbs.)
inches XLP POLY XLP POLY
AAC Neutral-messenger
Clydessdale 4 1 45 4 7 881 20.58 198 198 100 80
Pinto 4 7 45 4 7 881 20.58 211 211 100 80
Mustang 2 7 45 2 7 1350 25.42 318 318 135 105
Criollo 1/0 9 60 1/0 7 1990 25.42 503 503 180 140
Percheron 2/0 11 60 2/0 7 2510 29.97 619 619 205 160
Hanovarian 3/0 17 60 3/0 19 3310 35.18 764 764 235 185
Oldenburg 4/0 18 60 4/0 19 4020 35.18 945 945 275 210
Lippizaner 336.4 19 80 336.4 19 6146 38.79 1519 1519 370 280

*Code words for XLP insulated products are formed by adding "/XLP" to the conventional code words above (e.g.-Chihuahua/XLP)
+Conductor temperature of 90 for XLP,75 for Poly;ambient temperature of 40;emissivity 0.2;2ft./sec.Wind in sun