| Place of Origin: | China (Mainland) |
|---|---|
| Brand Name: | Flypower |
| Model Number: | BH-B2 |
| Material: | PE |
| Application: | High Voltage |
| Rated Voltage: | 1000v |
Quick Details
Specifications
BH-B2 is semi-flexible medium wall tubing with continuous length and without hot melt adhesive. Designed for applications to seal and protect 1KV power cable terminations and joints.
Minimum fully recovery temperature: 120
Standard color: Black, Red
Specification:
Technical Data:
Minimum fully recovery temperature: 120
Standard color: Black, Red
Specification:
|
Normal size (mm) |
As supplied (mm) |
After recovered (mm) | Style |
Standard length (mm) |
|
|
Inside diameter (min.) |
Inside diameter (Max.) |
Wall thickness (mm) |
|||
| 8/2 | 8 | 2 | 1.7 | — | 30 |
| 12/3 | 12 | 3 | 2.0 | — | 30 |
| 16/5 | 16 | 5 | 2.2 | — | 30 |
| 22/6 | 22 | 6 | 2.5 | — | 30 |
| 33/10 | 33 | 10 | 2.7 | — | 30 |
| 40/12 | 40 | 12 | 2.7 | — | 30 |
| 48/16 | 48 | 16 | 2.7 | — | 30 |
| 55/19 | 55 | 19 | 2.7 | — |
30
|
Technical Data:
| Property | Test Method | Typical Data |
| Operating temperature | IEC 216 | -55 to +110℃ |
| Tensile strength | ASTM D2671 | ≥14MPa |
| Elongation at break | ASTM D2671 | ≥600% |
| Density | ASTM D792 | 1.05g/cm3 |
| Longitudinal shrinkage | UL224 | 0 to -10% |
| Dielectric strength | IEC243 | ≥20kV/mm |
| Volume resistance | IEC93 | ≥1014Ω.cm |
| Dielectric constant | IEC250 | 3.0 |
| Water absorption | ISO 62/23℃,14days | <0.15% |