Product Main

Quick Details

Place of Origin: China (Mainland)
Brand Name: Dechuang
Model Number: DCRD1000B1
Application: Simple process conditions, corrosive liquids, slurries and such as

Specifications

Product Features:

1. cost-effective, durable, shorter lead time;

2. no blind spots, high precision, long measurement distance;

3. not affected by change of pressure, vacuum and temperature, or the environmental effect of inert gases, dust, steam, etc;

4. easy installation, maintenance-free;

5. communication protocols, simple calibration, easy field calibration operation through LCD display, simple configuration settings and programming by software;

6. sensitive measurement, high refresh speed;

7. suitable for high temperature conditions.


Technical Parameter:

Application

Simple process conditions, corrosive liquids, slurries and such as: waste water tanks, acid tanks, slurry tanks, solid particles, small oil storage tanks

Measuring range

20 meter

Process connection

G11/2 Screw or 11/2NPT

Medium Temperature

-40-120

Process pressure

-0.1-0.3Mpa

Repeatability

± 2mm

Precision  

±10mm

Frequency range

6.8GHz

Anti-explosion/safety grade

Exia IIC T6/IP67

Signal output

4...20mA/HART(Two-wire)

 

Model selection:

Explosion

P  standard (non-Ex) current signal output (4-20mA) HART protocol

I  Intrinsically Safe (Exia C T6) current signal output (4-20mA) HART protocol

D intrinsically safe explosion-proof (Exd ia C T6) current signal output (4-20mA) HART protocol

Antenna Type/ Material/ Process Temperature

SP  plastic rod / PP / -40 ... 100

SF  plastic rod / PTFE / -40 ... 120

Process connection

G  thread G11/2A

N  Threaded 11/2NPT

A  stainless steel flange DN50 PN16C type

B  type stainless steel flange DN80 PN16C

C  type stainless steel flange DN100 PN16C

D  type stainless steel flange DN150 PN16C

E  type stainless steel flange DN200 PN16C

F  type stainless steel flange DN250 PN16C

Container joint tube length

A  50mm

B  100mm

C  150mm

D  200mm

E  250mm

Y  special convention

Housing/ Protection class

P  Plastic / IP65

L  aluminum / IP67

Cable entry

M  M20 * 1.5

N  ?NPT

Site display

V  included

X  without

Programmer

B  included

X  without