 Basemed deliver Base850A ICU treatment ventilator, very stable performance, safe and reliable, Can be widely used in emergency, ICU room, operation room and internal medicine etc.

Features

 l 12.1 inch TFT color screen , big screen could show more information. 

 l Screen could be rotated freely, suitable to operate at any angle and height     

 l Integrated expiration module could be sterilized whole, ensure use safely and no cross-infection.

 l Expiration valve adopt no-water design, guarantee the precious detection. 

 l Could show Paw-t, Flow-t, Volume-t, Paw-V, Flow-V five waveform at the same time, also could show one or several waveform according to our operation.

 l Curve size, time scale, pressure-flow ratio adjustable, watch the details more good.    

 l Curve pause function, could watch details.

 l Sensitive flow, pressure two trigger function, could effect at a same time. 

 l Build-in inspiratory and expiration flow sensor, durable and water coagulation resistant.

 l Automatically inspiratory synchronous nebulizing function, nebulizing time adjustable;

 l 100% Oxygen inspiratory function, oxygen inspiratory time is adjustable.

 l Three-level visual and audible alarm, with concise words describing problems

 l Alarm record with clearance function , could record the last 100 pieces of information, show alarm grade, alarm time and the alarm parameter. 

 l Pressure, volume, time respiratory mode security, could inspect pressure in inspiratory phase, volume, time exceed the regulated value, turn into expiratory, ensure patient safety. 

 l Volume security function, keep the minimum tidal volume in pressure mode.

 l Adjust MMV function automatically, adjust inspiratory pressure and breathing frequency, approaching the target tidal volume and minute ventilator. 

 l Low noise medical air Compressor, very stable performance, safe and reliable.

 l VGA connector could output the screen signal to other screen

 l High quality trolley with concise structure and good appearance, easy to assembly and detach.  

Specification

    Operating Modes

  Volume Control Ventilation (VCV)

  Assisted/Controlled Pressure Control Ventilation (PCV),                      

  Assisted/Controlled Pressure Support Ventilation (PSV),

  SIMV(VCV)+PSV

  SIMV(PCV)+PSV

  Mandatory Minute Ventilation (MMV)

  Continuous Positive Airway Pressure(CPAP)

  Backup apnea ventilation              

   Parameter

 Application scope: Pediatric and adult

 Driven mode: pneumatically driven and electronically controlled

 Display: 12.1 TFT screen

 Working mode: Pressure and volume

 Ventilation wave type: squire wave, deceleration wave

 FiO2: 21% to 100%

 PEEP/CPAP: 0 to 40 cmH2O

 Inspiratory Sensitivity:

 Flow triggered: 0.5 to 20 L/min, OFF

 Pressure triggered: -1 to -20 cmH2O, OFF                                 

 Tidal Volume: 20 to 2000 mL

  Breath frequency: 1 to 100 bpm

  I:E Ratio: 5.0 : 1 to 1 : 5.0

  Inspiratory plateau: 0 to 50%

  Inspiratory Flow Wave Shape(VCV): Rectangular wave and Decelerating wave

  SIGH: 1.0 to 2.0

  Breath frequency(SIMV): 2 to 40bpm

  Inspiratory time (SIMV): 0.1 to 12 S

  Pressure Support Ventilation (PSV): 0 to 40 cmH2O

  Expiratory Sensitivity for PSV : 10% to 75% of the initial flow

  Maximum Inspiratory time (PSV): 1.0 to 8.0 S

  Pressure Control Ventilation(PCV): 0 to 40 cmH2O

  Minimum Tidal Volume(PCV and PSV): 50 to 1500 mL                                        

  Backup Rate (PSV): 2 to 40 bpm

  Object Tidal Volume(MMV): 20 to 2000 mL

  Ventilation volume(MMV): 0.5 to 40.0 L/min

  Nebulizer time: 30 minutes

     Monitoring

  Breathing wave: Pressure vs time curve, Flow vs time curve,Volume vs time curve, Pressure vs volume loops,Flow vs volume loops

  Expiratory tidal volume:,

  Breath frequency(bpm),

  PEEP:

  FiO2

  MV

  Insipiratory Tidal volume(TV_Insp):              

  I:E ratio:

  Freq_indepen:

  MV_Indepen:

  Pmean

  Pflat:,

  Airway Pressure

  Ppeak,

  Minute Ventilation,

  Oxygen concentration                                          

    Alarms

  High tidal volume alarm

  Low tidal volume alarm

  High minute ventilation alarm

  Low minute ventilation alarm

  High breathing frequency alarm

  Low breathing frequency alarm

  High peak pressure alarm

  Low peak pressure alarm                                            

  High PEEP pressure alarm

  Low PEEP pressure alarm

  High oxygen concentration alarm

  Low oxygen concentration alarm

  Apnea alarm

  AC power fail alarm

  Air source Low pressure alarm

  Oxygen source low pressure alarm

  Battery disconnect alarm

  Low battery alarm

  Circle leakage alarm

  Circle block alarm

   POWER REQUIREMENT

  Main power: from 85 to 265VAC 47-63HZ

  AC/DC switch automatically

  Internal battery: 12VDC; 7AH

  Automatic recharge.

  Estimated duration: more than 2 hours when completely charged.

  The display shows an icon with the charge level.

    PNEUMATIC REQUIREMENT

  Oxygen: pressure 2.8 to 6 bar ISO5359 connector

  Air: pressure 2.8 to 6 bar ISO 5359 connector