Place of Origin: | China (Mainland) |
---|---|
Brand Name: | LIXISE |
Model Number: | ATS106 |
Output Type: | |
Speed: | |
Frequency: | |
Rated Power: | |
Rated Voltage: | |
Rated Current: | |
Type: | Diesel Generator |
Brand: | LIXISE |
Quick Details
Specifications
Products:
ATS106 dual power transfer controller for mains / generator automatic switching control module, which microprocessor core, can accurately detect two single-phase voltage, the voltage that appears abnormal (loss of power, overvoltage, undervoltage, too frequent, less frequent) to make accurate judgments, ATS after delay control switch. The controller has issued a starter mains signal generators feature abnormal delay.
Product performance and features:
1, all the way to adapt to the way electricity generation ATS control
2, W (8-35) power supply range VDC, can adapt to different starting battery voltage generators environment.
3, mains or generator voltage threshold can be set, the normal time delay can be set, generator set start delay can be set.
4, mains voltage abnormal delay can be set, generators stop delay can be set.
5, 7 LED on the front panel display various operating and alarm status.
6, switching relay contact capacity 16A 250VAC, can directly drive the switching.
7, generators power relay (GNES START) Output contact capacity 5A 250VAC, for passive contact.
8, USB programming interface, work for all kinds of delays, power thresholds can be set via a PC.
Specifications:
DC Power: 8 ~ 35V
AC sampling input: Single phase AC10 ~ 400V, 50 / 60Hz
ATS switching output: 5A250VAC passive relay contacts
Generator set power output: 5A250VAC passive relay contacts
2 closing state input: connected B-
Power Consumption: Standby (12V: 0.2W, 24V: 0.3W), normal operation (12V: 0.9W, 24V: 1.0W)
Working environment: Temperature: -30 ~ + 70 ℃ Humidity: 20 ~ 95%
Dimensions: 72 × 72 × 38mm
Hole Size: 67 × 67mm
Weight: 0.15Kg
ATS106 dual power transfer controller for mains / generator automatic switching control module, which microprocessor core, can accurately detect two single-phase voltage, the voltage that appears abnormal (loss of power, overvoltage, undervoltage, too frequent, less frequent) to make accurate judgments, ATS after delay control switch. The controller has issued a starter mains signal generators feature abnormal delay.
Product performance and features:
1, all the way to adapt to the way electricity generation ATS control
2, W (8-35) power supply range VDC, can adapt to different starting battery voltage generators environment.
3, mains or generator voltage threshold can be set, the normal time delay can be set, generator set start delay can be set.
4, mains voltage abnormal delay can be set, generators stop delay can be set.
5, 7 LED on the front panel display various operating and alarm status.
6, switching relay contact capacity 16A 250VAC, can directly drive the switching.
7, generators power relay (GNES START) Output contact capacity 5A 250VAC, for passive contact.
8, USB programming interface, work for all kinds of delays, power thresholds can be set via a PC.
Specifications:
DC Power: 8 ~ 35V
AC sampling input: Single phase AC10 ~ 400V, 50 / 60Hz
ATS switching output: 5A250VAC passive relay contacts
Generator set power output: 5A250VAC passive relay contacts
2 closing state input: connected B-
Power Consumption: Standby (12V: 0.2W, 24V: 0.3W), normal operation (12V: 0.9W, 24V: 1.0W)
Working environment: Temperature: -30 ~ + 70 ℃ Humidity: 20 ~ 95%
Dimensions: 72 × 72 × 38mm
Hole Size: 67 × 67mm
Weight: 0.15Kg